Product Description:
Surge arrester type 2, consisting of base element and protective plug with N-PE total current spark gap for mounting on NS 35/7.5, housing width: 17.5 mm (1 Div.)

GTIN
: 04017918163662
Series
: F-MS 12
Type
: Overspanningsbeveiliging Type 2
Key Features
- Surge arrester type 2
- consisting of base element and protective plug with N-PE total current spark gap for mounting on NS 35/7.5
- housing width: 17.5 mm
Advantages
• Single-channel, DIN-rail mountable protective devices
• Consists of base element and plug
• Base element with/without floating remote indication contact
• Disconnect device on each individual plug
• Optical, mechanical status indication for the individual arresters
• Mechanical coding of all slots
Training Data Goes here
Dimensions
Height
89.8 mm
Width
17.6 mm
Depth
65.7 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
1
Ambient conditions
Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40 °C ... 80 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
General
IEC test classification
II
IEC test classification
T2
EN type
T2
IEC power supply system
TN
IEC power supply system
TT
Mode of protection
N-PE
Mounting type
DIN rail: 35 mm
Color
jet black RAL 9005
Housing material
PA 6.6
Housing material
PBT
Degree of pollution
2
Flammability rating according to UL 94
V-0
Type
DIN rail module, two-section, divisible
Number of positions
1
Surge protection fault message
optical
Protective circuit
Nominal voltage UN
240/415 V AC (TN - only N-PE)
Nominal voltage UN
240/415 V AC (TT - only N-PE)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
260
Rated load current IL
80
Residual current IPE
≤ 5 µA
Standby power consumption PC
≤ 1.5 mVA
Nominal discharge current In (8/20) µs
20
Maximum discharge current Imax (8/20) µs
40
Follow current interrupt rating Ifi
100
Voltage protection level Up
≤ 1.5 kV
Residual voltage Ures
≤ 0.4 kV (at In)
Residual voltage Ures
≤ 0.25 kV (at 10 kA)
Residual voltage Ures
≤ 0.15 kV (at 5 kA)
Residual voltage Ures
≤ 0.1 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs
≤ 1.5 kV
TOV behavior at UT
1200 V AC (200 ms / withstand mode)
Response time tA
≤ 100 ns
Max. backup fuse with V-type through wiring
80 A (gG)
Connection data
Connection method
Screw connection
Screw thread
M5
Tightening torque
3 Nm (1.5 mm² ... 16 mm²)
Tightening torque
4.5 Nm (25 mm² ... 35 mm²)
Stripping length
16
Conductor cross section flexible
1.5 mm² ... 25 mm²
Conductor cross section solid
1.5 mm² ... 35 mm²
Conductor cross section AWG
15 ... 2
Connection method
Fork-type cable lug
Conductor cross section flexible
1.5 mm² ... 16 mm²
UL specifications
SPD Type
4CA
Maximum continuous operating voltage MCOV (N-G)
260
Mode of protection
N-G
Power distribution system
Single phase
Nominal frequency
50/60 Hz
Measured limiting voltage MLV (N-G)
1490
Nominal discharge current In (N-G)
20
UL connection data
Conductor cross section AWG
10 ... 2
Tightening torque
30
Standards and Regulations
Standards/regulations
IEC 61643-11 2011
Standards/regulations
EN 61643-11 2012
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years
CCA NTR-AT 1947-A
EAC RU C-DE.*09.B.00169
cULus Recognized
CLASS II standard fulfilled in acc. with IEC 61643-1 (pdf154 KB)