Product Description:
Trunk line branch terminal, nom. voltage: 400 V, nominal current: 125 A, connection method: Screw connection, Screw connection, number of connections: 4, number of positions: 1, cross section: 10 mm² - 35 mm², AWG: 8 - 2, width: 27 mm, color: blue, mounting type: NS 35/7,5, NS 35/15

GTIN
: 04046356735988
Series
: UDB 2X35/25 BU
Type
: Hoofdleidingsaftakklem
Key Features
- Trunk line .ranch terminal
- nom. voltage: 400 V
- nominal current: 125 A
- connection method: Screw connection
- Screw connection
- number of connections: 4
- number of positions: 1
- cross section: 10 mm² - 35 mm²
- AWG: 8 - 2
- width: 27 mm
- color: blue
- mounting type: NS 35/7
- NS 35/15
Advantages
• The branch terminal is suitable for the simple voltage pick-off of main supply cables
• Conformance with DIN VDE 0603‑2/EN 60998‑1
Training Data Goes here
General
Number of positions
1
Number of levels
1
Number of connections
4
Potentials
1
Nominal cross section
35
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
4.06 W
Maximum load current
125
Nominal current IN
125
Nominal voltage UN
400 V (max. 1000 V)
Open side panel
No
Dimensions
Width
27
Length
55
Height NS 35/7,5
46
Height NS 35/15
53.5 mm
Connection data
Connection
1
Connection method
Screw connection
Screw thread
M6/M8
Stripping length
25
Tightening torque max
4
Connection in acc. with standard
IEC 60998-1
Note
Use ferrules for stranded conductors
Conductor cross section solid min.
10
Conductor cross section solid max.
35
Conductor cross section AWG min.
8
Conductor cross section AWG max.
2
Conductor cross section flexible min.
10
Conductor cross section flexible max.
25
Min. AWG conductor cross section, flexible
8
Max. AWG conductor cross section, flexible
3
Conductor cross section flexible, with ferrule without plastic sleeve min.
10
Conductor cross section flexible, with ferrule without plastic sleeve max.
25
Conductor cross section flexible, with ferrule with plastic sleeve min.
10
Conductor cross section flexible, with ferrule with plastic sleeve max.
16
Connection
2nd level
Conductor cross section solid min.
1.5 mm²
Conductor cross section solid max.
25
Conductor cross section flexible, with ferrule without plastic sleeve min.
1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
16
Conductor cross section flexible, with ferrule with plastic sleeve min.
1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
10
Ambient conditions
Operating temperature
-60 °C ... 85 °C
Ambient temperature (storage/transport)
-25 °C ... 55 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.A*30.B.01742