Product Description:
Trunk line branch terminal, nom. voltage: 400 V, nominal current: 101 A, connection method: Screw connection, Screw connection, number of connections: 4, number of positions: 1, cross section: 1.5 mm² - 25 mm², AWG: 8 - 2, width: 23 mm, color: green, mounting type: NS 35/7,5, NS 35/15

GTIN
: 04046356736046
Series
: UDB 2X25/16 GN
Type
: Hoofdleidingsaftakklem
Key Features
- Trunk line .ranch terminal
- nom. voltage: 400 V
- nominal current: 101 A
- connection method: Screw connection
- Screw connection
- number of connections: 4
- number of positions: 1
- cross section: 1.5 mm² - 25 mm²
- AWG: 8 - 2
- width: 23 mm
- color: green
- mounting type: NS 35/7
- NS 35/15
Advantages
• The branch terminal is suitable for the simple voltage pick-off of main supply cables
• Conformance with DIN VDE 0603‑2/EN 60998‑1
Training Data Goes here
General
Number of positions
1
Number of levels
1
Number of connections
4
Potentials
1
Nominal cross section
25
Color
green
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
3.26 W
Maximum load current
101
Nominal current IN
101
Nominal voltage UN
400 V (max. 1000 V)
Open side panel
No
Dimensions
Width
23
Length
46
Height NS 35/7,5
42
Height NS 35/15
49.5 mm
Connection data
Connection
1
Connection method
Screw connection
Screw thread
M5/M6
Stripping length
16
Tightening torque, min
2.2 Nm
Tightening torque max
2.5 Nm
Connection in acc. with standard
IEC 60998-1
Note
Use ferrules for stranded conductors
Conductor cross section solid min.
1.5 mm²
Conductor cross section solid max.
25
Conductor cross section AWG min.
8
Conductor cross section AWG max.
2
Conductor cross section flexible min.
10
Conductor cross section flexible max.
16
Min. AWG conductor cross section, flexible
8
Max. AWG conductor cross section, flexible
3
Conductor cross section flexible, with ferrule without plastic sleeve min.
1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
16
Conductor cross section flexible, with ferrule with plastic sleeve min.
1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
10
Connection
2nd level
Tightening torque, min
1.7 Nm
Tightening torque max
2
Conductor cross section solid max.
16
Conductor cross section flexible, with ferrule without plastic sleeve max.
10
Conductor cross section flexible, with ferrule with plastic sleeve max.
6
Ambient conditions
Operating temperature
-60 °C ... 85 °C
Ambient temperature (storage/transport)
-25 °C ... 55 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.A*30.B.01742