Test disconnect terminal block, with slide, connection method: Screw connection, cross section: 0.5 mm² - 10 mm² , AWG: 20 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: red
GTIN
: 04017918233815
Series
: URTK/S RD
Type
: Meettransformator-scheidingsklem
Key Features
- Test d.sconnect terminal block
- with slide
- connection method: Screw connection
- cross section: 0.5 mm² - 10 mm²
- AWG: 20 - 10
- width: 8.2 mm
- mounting type: NS 35/7
- NS 35/15
- NS 32
- color: red
Advantages
• Easy and clear testing in current transformer secondary circuits can be performed using the test disconnect terminal blocks of the URTK/S range
• On both sides of the disconnect point, the terminal block has a test socket which can also be used to switch across to neighboring terminal blocks
Training Data Goes here
General
Number of levels
1
Number of connections
2
Potentials
1
Nominal cross section
6
Color
red
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
6
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.31 W
Maximum load current
57 A (with 10 mm² conductor cross section)
Nominal current IN
41
Nominal voltage UN
400
Open side panel
Yes
Dimensions
Width
8.2 mm
End cover width
2.2 mm
Length
72
Height NS 35/7,5
51.5 mm
Height NS 35/15
59
Height NS 32
56.5 mm
Connection data
Note
Terminal point
Connection
1
Connection method
Screw connection
Screw thread
M4
Stripping length
13
Tightening torque, min
1.2 Nm
Tightening torque max
1.5 Nm
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
10
Conductor cross section AWG min.
20
Conductor cross section AWG max.
8
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
6
Min. AWG conductor cross section, flexible
20
Max. AWG conductor cross section, flexible
10
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
6
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
4
2 conductors with same cross section, solid min.
0.5 mm²
2 conductors with same cross section, solid max.
2.5 mm²
2 conductors with same cross section, stranded min.
0.5 mm²
2 conductors with same cross section, stranded max.
6
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
4
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
4
Internal cylindrical gage
A5
Ambient conditions
Operating temperature
-60 °C ... 85 °C
Ambient temperature (storage/transport)
-25 °C ... 55 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CUL
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values