Phoenix Contact Temperature measuring transducer - MACX MCR-T-UIREL-UP-SP - 2811828
Product Description:
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

GTIN
: 04046356579483
Series
: MACX MCR-T-UIREL-UP-SP
Type
: Temperatuurmeetwaardeomvormers
Key Features
- Freely programmable temperature transducer with analog output and 3 limit value relays
- standard configuration
- resistance thermometer in 2-
- 3-
- 4-conductor technology
- thermocouples
- electrical isolation
- wide-range power supply
- Push-in connection
- SIL
- PL.
Advantages
• Cold junction compensation with separate plug
• Configuration via software (FDT/DTM) or IFS-OP-UNIT operator interface and display unit
• Installation in zone 2, protection type "n" (EN 60079-15) permitted
• Up to SIL 2 according to EN 61508
• Plug-in screw or spring-cage connection technology (Push-in technology)
• Three limit value relays, can be used in combination as a safe limit value relay
• Programming during operation and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
• Input for resistance thermometers, thermocouples, resistance-type sensors, potentiometers, and mV sources
• Measure differential temperatures
• Freely programmable input and output
• Inverse output signal ranges as an option
Training Data Goes here
Dimensions
Width
35
Height
116
Depth
113.7 mm
Depth
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)
Ambient conditions
Ambient temperature (operation)
-20 °C ... 65 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Maximum altitude
≤ 2000 m
Permissible humidity (operation)
typ. 5 % ... 95 % (non-condensing)
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Input data
Sensor types (RTD) that can be used
Pt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)
B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Temperature measuring range
-250 °C ... 2500 °C (Range depending on the sensor type)
Input signal range
0 Ω ... 50 kΩ
Potentiometer resistance range
0 Ω ... 50 kΩ
Input signal range
-1000 mV ... 1000 mV
Output data
Configurable/programmable
Yes
Max. voltage output signal
± 11 V
Current output signal
4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Max. current output signal
22
Load/output load voltage output
≥ 10 kΩ
Load/output load current output
≤ 600 Ω (at 20 mA)
Behavior in the event of a sensor error
according to NE 43 or freely configurable
Output name
Relay output
Contact type
3 changeover contacts
Contact material
AgSnO2, hard gold-plated
Maximum switching voltage
250 V AC (250 V DC)
Maximum inrush current
2 A (250 V AC)
Maximum inrush current
2 A (28 V DC)
Power supply
Supply voltage range
24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Power consumption
< 2.4 W
Connection data
Connection method
Push-in connection
Stripping length
8
Conductor cross section solid
0.2 mm² ... 1.5 mm²
Conductor cross section flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
General
Maximum transmission error
0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Maximum temperature coefficient
0.01 %/K
Degree of pollution
2
Overvoltage category
II
Electromagnetic compatibility
Conformance with EMC directive
Interference emission
EN 61000-6-4
Housing material
PA 6.6-FR
Color
gray
Designation
Input/output/power supply
Rated insulation voltage
300
Test voltage
2.5 kV AC (50 Hz, 1 min.)
Insulation
Safe isolation in accordance with IEC/EN 61010-1
Designation
Input/output
Electrical isolation
375 V (Peak value in accordance with IEC/EN 60079-11)
Designation
Input/power supply
Designation
Input/switching output
Standards and Regulations
Noise emission
EN 61000-6-4
Electrical isolation
4-way, between input/output/power supply/switching output
Conformance/approvals
Designation
CE
Certificate
----
Designation
ATEX
Identification
II 3 G Ex nA nC ic IIC T4 Gc X
Certificate
IBExU 10 ATEX B001 X
Designation
IECEx
Identification
Ex nA nC ic IIC T4 Gc X
Certificate
IECEx IBE 10.0011 X
Designation
UL, USA/Canada
Identification
UL 508 Listed
Identification
Class I, Div. 2, Groups A, B, C, D T6
Identification
Class I, Zone 2, Group IIC T6
Designation
Shipbuilding approval
Certificate
DNV GL TAA000020C
Designation
Safety Integrity Level (SIL, IEC 61508)
Identification
2
Temperature
B
Humidity
B
Vibration
A
EMC
A
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years