Product Description:
Attachment plug with surge protection for antenna inputs with TV connector

GTIN
: 04017918915186
Series
: C-TV/HIFI
Type
: Overspanningsbeveiligingsmoduul
Key Features
- Attachment plug with surge protection for antenna inputs with TV connector
Advantages
• No signal interference with optimum transmission properties
• Space-saving, thanks to the compact design
• Ideal addition to the C-SAT-Box for direct end-device protection
Training Data Goes here
Dimensions
Height
40
Width
28
Depth
61
Ambient conditions
Ambient temperature (operation)
-25 °C ... 75 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Degree of protection
IP20
General
Housing material
PA 6.6
Flammability rating according to UL 94
V-0
Color
jet black RAL 9005
Overvoltage category
II
Degree of pollution
2
Mounting type
Connection-specific intermediate plugging
Type
Attachment plug
Number of positions
1
Direction of action
Line-Shield/Earth Ground
Protective circuit
IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1
Maximum continuous voltage UC
24
Rated current
1.5 A (25 °C)
Operating effective current IC at UC
≤ 1 µA
Residual current IPE
≤ 1 µA
Nominal discharge current In (8/20) µs (line-shield)
2.5 kA
Nominal pulse current Ian (10/1000) µs (line-shield)
120
Output voltage limitation at 1 kV/µs (line-shield) spike
≤ 600 V
Output voltage limitation at 1 kV/µs (line-shield) static
≤ 600 V
Residual voltage at In (line-shield)
≤ 30 V
Voltage protection level Up (line-shield)
≤ 700 V (C2 - 4 kV / 2 kA)
Voltage protection level Up (line-shield)
≤ 800 V (C2 - 5 kV/2,5 kA)
Response time tA (line-shield)
≤ 100 ns
Input attenuation aE, asym.
typ. 0.5 dB (≤ 2.4 GHz /75 Ω)
Cut-off frequency fg (3 dB), asym. (shield) in 75 Ω system
> 1 GHz
Frequency range
4.7 MHz ... 860 MHz
Capacity asymmetrical (shield)
typ. 10 pF
Surge protection fault message
none
Impulse durability (line-shield)
C2 - 4 kV/2 kA
Impulse durability (line-shield)
C2 - 5 kV / 2.5 kA
Impulse durability (line-shield)
C3 - 100 A
Impulse durability (line-shield)
D1 - 500 A
Alternating current carrying capacity (line-shield)
5 A - 1 s
Pulse reset time (line-shield)
< 3 s
Connection data
Connection method
PAL-TV (IEC 169-2)
Connection method IN
Socket
Connection method OUT
Male
Standards and Regulations
Standards/specifications
IEC 61643-21 2012
Standards/specifications
EN 61643-21 2013
Standards/specifications
EN 50083 CLASS-A
EAC RU C-DE.*09.B.00169