Product Description:
PCB terminal block, nominal current: 76 A, rated voltage (III/2): 1000 V, nominal cross section: 16 mm², pitch: 15 mm, number of positions: 7, connection method: Push-lock spring connection, mounting: Wave soldering, conductor/PCB connection direction: 0 °, color: green, Pin layout: Linear double pinning, Solder pin [P]: 4.5 mm

GTIN
: 04046356458184
Series
: PLH 16/ 7-15
Type
: Printklem
Key Features
- PCB terminal block
- nominal current: 76 A
- rated voltage : 1000 V
- nominal cross section: 16 mm²
- pitch: 15 mm
- number of positions: 7
- connection method: Push-lock spring connection
- mounting: Wave soldering
- conductor/PCB connection direction: 0 °
- color: green
- Pin layout: Linear double pinning
- Solder pin [P]: 4.5 mm
Advantages
• Tool-free lever principle enables time-saving connection and release of conductors with/without ferrules
• Defined contact force ensures that contact remains stable over the long term
• Time-saving push-in connection when lever is closed
• Quick and convenient testing using integrated test option
Training Data Goes here
Item properties
Brief article description
PCB terminal block
Range of articles
PLH 16/
Pitch
15
Number of positions
7
Mounting type
Wave soldering
Pin layout
Linear double pinning
Number of levels
1
Number of connections
7
Number of potentials
7
Electrical parameters
Nominal current
76
Nom. voltage
1000
Contact resistance
Test passed IEC 60512-2-1:2002-02
Rated voltage (III/3)
1000
Rated voltage (III/2)
1000
Rated voltage (II/2)
1000
Rated surge voltage (III/3)
8
Rated surge voltage (III/2)
8
Rated surge voltage (II/2)
8
Connection capacity
Connection method
Push-lock spring connection
Conductor cross section solid
0.75 mm² ... 16 mm²
Conductor cross section flexible
0.75 mm² ... 25 mm²
Conductor cross section AWG / kcmil
18 ... 4
Conductor cross section flexible, with ferrule without plastic sleeve
0.75 mm² ... 16 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.75 mm² ... 10 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.75 mm² ... 4 mm²
Stripping length
18
Material data - contact
Note
WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material
Cu alloy
Surface characteristics
Tin-plated
Metal surface terminal point (top layer)
Tin (10 - 16 µm Sn)
Metal surface soldering area (top layer)
Tin (10 - 16 µm Sn)
Material data - housing
Housing color
green (6021)
Insulating material
PA
Insulating material group
I
CTI according to IEC 60112
600
Flammability rating according to UL 94
V0
Glow wire flammability index GWFI according to EN 60695-2-12
850
Glow wire ignition temperature GWIT according to EN 60695-2-13
775
Temperature for the ball pressure test according to EN 60695-10-2
125
Dimensions for the product
Dimensional drawing
----
Caption
Schematische Abbildung - weitere Details siehe Produktfamilienzeichnung im Download Center
Length [ l ]
30.5 mm
Width [ w ]
101.4 mm
Height [ h ]
29
Height (without solder pin)
33.5 mm
Solder pin [P]
4.5 mm
Pin spacing
12.5 mm
Pin dimensions
1.2 x 1.2 mm
Dimensions for PCB design
Hole diameter
1.6 mm
Packaging information
Type of packaging
packed in cardboard
Pieces per package
25
Denomination packing units
Pcs.
Outer packaging type
----
Ambient conditions
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Ambient temperature (assembly)
-5 °C ... 100 °C
Ambient temperature (operation)
-40 °C ... 100 °C (Depending on the current carrying capacity/derating curve)
Termination and connection method
Test – repeated connection and release
IEC 60999-1:1999-11
Test – repeated connection and release
Test passed
Test for conductor damage and slackening
IEC 60999-1:1999-11
Test for conductor damage and slackening
Test passed
Pull-out test
Pull-out test
IEC 60999-1:1999-11
Conductor cross section / conductor type / tensile force
0.75 mm² / solid / > 30 N
Conductor cross section / conductor type / tensile force
0.75 mm² / flexible / > 30 N
Conductor cross section / conductor type / tensile force
16 mm² / stranded / > 100 N
Conductor cross section / conductor type / tensile force
16 mm² / flexible / > 100 N
Conductor cross section / conductor type / tensile force
10 mm² / flexible with ferrule / > 90 N
Mechanical tests according to standard
Test specification
IEC 60947-7-4
Electrical tests
Rated current
76
Conductor cross section
25
Air clearances and creepage distances
Clearances and creepage distances
IEC 60664-1:2007-04
Specification
IEC 60664-1:2007-04
Minimum clearance - inhomogeneous field (III/3)
8
Minimum clearance - inhomogeneous field (III/2)
8
Minimum clearance - inhomogeneous field (II/2)
5.5 mm
Minimum creepage distance value (III/3)
12.5 mm
Minimum creepage distance value (III/2)
8
Minimum creepage distance value (II/2)
5.5 mm
Temperature-rise test
Specification
IEC 60947-7-4:2013-08
Requirement temperature-rise test
The sum of ambient temperature and temperature rise of the PCB terminal block shall not exceed the upper limiting temperature.
Current carrying capacity / derating curves
Diagram
----
Caption
Type: PLH 16/...-15Tested in accordance with DIN EN 60512-5-2:2003-01No. of positions: 5Conductor cross section: 16 mm² (exclusively for solid conductors)
Vibration test
Specification
IEC 60068-2-6:2007-12
Frequency
10 - 150 - 10 Hz
Sweep speed
1
Amplitude
0.35 mm (10 - 60.1 Hz)
Acceleration
5 g (60.1 - 150 Hz)
Test duration per axis
2.5 h
Insulation resistance
Specification
IEC 60512-3-1:2002-02
Result
Test passed
Insulation resistance, neighboring positions
> 5 MΩ
Glow-wire test
Specification
IEC 60695-2-10:2000-10
Temperature
850
Time of exposure
5
Alternating climate test
Specification
ISO 6988:1985-02
Standards and Regulations
Connection in acc. with standard
UL
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values