Product Description:
PCB terminal block, nominal current: 76 A, rated voltage (III/2): 400 V, nominal cross section: 16 mm², pitch: 10 mm, number of positions: 1, connection method: Push-lock spring connection, mounting: Wave soldering, conductor/PCB connection direction: 0 °, color: green, Pin layout: Linear double pinning, Solder pin [P]: 4.5 mm

GTIN
: 04046356671804
Series
: PLH 16/ 1-10
Type
: Printklem
Key Features
- PCB terminal block
- nominal current: 76 A
- rated voltage : 400 V
- nominal cross section: 16 mm²
- pitch: 10 mm
- number of positions: 1
- connection method: Push-lock spring connection
- mounting: Wave soldering
- conductor/PCB connection direction: 0 °
- color: green
- Pin layout: Linear double pinning
- Solder pin [P]: 4.5 mm
Advantages
• Tool-free lever principle enables time-saving connection and release of conductors with/without ferrules
• Defined contact force ensures that contact remains stable over the long term
• Time-saving push-in connection when lever is closed
• Quick and convenient testing using integrated test option
Training Data Goes here
Item properties
Brief article description
PCB terminal block
Range of articles
PLH 16/
Pitch
10
Number of positions
1
Mounting type
Wave soldering
Pin layout
Linear double pinning
Number of levels
1
Number of connections
1
Number of potentials
1
Electrical parameters
Nominal current
76
Nom. voltage
400
Contact resistance
Test passed IEC 60512-2-1:2002-02
Rated voltage (III/3)
400
Rated voltage (III/2)
400
Rated voltage (II/2)
800
Rated surge voltage (III/3)
4
Rated surge voltage (III/2)
4
Rated surge voltage (II/2)
4
Connection capacity
Connection method
Push-lock spring connection
Conductor cross section solid
0.75 mm² ... 16 mm²
Conductor cross section flexible
0.75 mm² ... 25 mm²
Conductor cross section AWG / kcmil
18 ... 4
Conductor cross section flexible, with ferrule without plastic sleeve
0.75 mm² ... 16 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.75 mm² ... 10 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.75 mm² ... 4 mm²
Stripping length
18
Material data - contact
Note
WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material
Cu alloy
Surface characteristics
Tin-plated
Metal surface terminal point (top layer)
Tin (10 - 16 µm Sn)
Metal surface soldering area (top layer)
Tin (10 - 16 µm Sn)
Material data - housing
Housing color
green (6021)
Insulating material
PA
Insulating material group
I
CTI according to IEC 60112
600
Flammability rating according to UL 94
V0
Glow wire flammability index GWFI according to EN 60695-2-12
850
Glow wire ignition temperature GWIT according to EN 60695-2-13
775
Temperature for the ball pressure test according to EN 60695-10-2
125
Dimensions for the product
Dimensional drawing
----
Caption
Schematische Abbildung - weitere Details siehe Produktfamilienzeichnung im Download Center
Length [ l ]
30.5 mm
Width [ w ]
11.4 mm
Height [ h ]
33.5 mm
Height (without solder pin)
29
Solder pin [P]
4.5 mm
Pin spacing
12.5 mm
Pin dimensions
1.2 x 1.2 mm
Dimensions for PCB design
Hole diameter
1.6 mm
Packaging information
Type of packaging
packed in cardboard
Pieces per package
25
Denomination packing units
Pcs.
General product information
Type of note
Notes on operation
Note
The single-position PCB terminal block can be used for voltages up to 1500 V (DC) and 1000 V (AC). The relevant device standard and the appropriate required air clearances and creepage distances should be observed following installation
Ambient conditions
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Ambient temperature (assembly)
-5 °C ... 100 °C
Ambient temperature (operation)
-40 °C ... 100 °C (Depending on the current carrying capacity/derating curve)
Termination and connection method
Test result
Test passed
Test – repeated connection and release
IEC 60999-1:1999-11
Test – repeated connection and release
Test passed
Test for conductor damage and slackening
IEC 60999-1:1999-11
Test for conductor damage and slackening
Test passed
Pull-out test
Pull-out test
IEC 60999-1:1999-11
Conductor cross section / conductor type / tensile force
0.75 mm² / solid / > 30 N
Conductor cross section / conductor type / tensile force
0.75 mm² / flexible / > 30 N
Conductor cross section / conductor type / tensile force
16 mm² / stranded / > 100 N
Conductor cross section / conductor type / tensile force
16 mm² / flexible / > 100 N
Conductor cross section / conductor type / tensile force
10 mm² / flexible with ferrule / > 90 N
Mechanical tests according to standard
Test specification
IEC 60947-7-4
Electrical tests
Rated current
76
Conductor cross section
25
Air clearances and creepage distances
Clearances and creepage distances
IEC 60664-1:2007-04
Specification
IEC 60664-1:2007-04
Minimum clearance - inhomogeneous field (III/3)
3
Minimum clearance - inhomogeneous field (III/2)
3
Minimum clearance - inhomogeneous field (II/2)
3
Minimum creepage distance value (III/3)
5
Minimum creepage distance value (III/2)
3
Minimum creepage distance value (II/2)
4
Temperature-rise test
Specification
IEC 60947-7-4:2013-08
Requirement temperature-rise test
The sum of ambient temperature and temperature rise of the PCB terminal block shall not exceed the upper limiting temperature.
Current carrying capacity / derating curves
Diagram
----
Caption
Type: PLH 16/...-10Tested according to DIN EN 60512-5-2:2003-01Number of positions: 4Conductor cross section: 16 mm²
Vibration test
Specification
IEC 60068-2-6:2007-12
Frequency
10 - 150 - 10 Hz
Sweep speed
1
Amplitude
0.35 mm (10 - 60.1 Hz)
Acceleration
5 g (60.1 - 150 Hz)
Test duration per axis
2.5 h
Insulation resistance
Specification
IEC 60512-3-1:2002-02
Result
Test passed
Insulation resistance, neighboring positions
> 5 MΩ
Glow-wire test
Specification
IEC 60695-2-10:2000-10
Temperature
850
Time of exposure
5
Alternating climate test
Specification
ISO 6988:1985-02
Standards and Regulations
Connection in acc. with standard
UL
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values