Product Description:
PCB terminal block, nominal current: 76 A, rated voltage (III/2): 320 V, nominal cross section: 10 mm², pitch: 10 mm, number of positions: 1, connection method: Screw connection with tension sleeve, mounting: Wave soldering, conductor/PCB connection direction: 0 °, color: green, Pin layout: Linear pinning, Solder pin [P]: 4.3 mm. The article can be aligned to create different nos. of positions!

GTIN
: 04017918023164
Series
: KDS 10
Type
: Printklem
Key Features
- PCB terminal block
- nominal current: 76 A
- rated voltage : 320 V
- nominal cross section: 10 mm²
- pitch: 10 mm
- number of positions: 1
- connection method: Screw connection with tension sleeve
- mounting: Wave soldering
- conductor/PCB connection direction: 0 °
- color: green
- Pin layout: Linear pinning
- Solder pin [P]: 4.3 mm. The article can be aligned to create different nos. of positions!
Advantages
• Well-known connection principle allows worldwide use
• Low temperature rise, thanks to maximum contact force
• Allows connection of two conductors
• Potentials can be easily looped through with additional connection to the PCB
• The latching on the side enables various numbers of positions to be combined
Training Data Goes here
Item properties
Brief article description
PCB terminal block
Range of articles
KDS10
Pitch
10
Number of positions
1
Drive form screw head
Slotted
Screw thread
M4
Mounting type
Wave soldering
Pin layout
Linear pinning
Number of levels
1
Number of connections
2
Number of potentials
1
Electrical parameters
Nominal current
76
Nom. voltage
320
Rated voltage (III/3)
250
Rated voltage (III/2)
320
Rated voltage (II/2)
630
Rated surge voltage (III/3)
4
Rated surge voltage (III/2)
4
Rated surge voltage (II/2)
4
Connection capacity
Connection method
Screw connection with tension sleeve
pluggable
Yes
Conductor cross section solid
0.5 mm² ... 16 mm²
Conductor cross section flexible
0.5 mm² ... 10 mm²
Conductor cross section AWG / kcmil
20 ... 6
Conductor cross section flexible, with ferrule without plastic sleeve
0.5 mm² ... 10 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.5 mm² ... 10 mm²
2 conductors with same cross section, solid
0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible
0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.5 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 6 mm²
Stripping length
12
Torque
1.2 Nm ... 1.5 Nm
Material data - contact
Note
WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material
Cu alloy
Surface characteristics
Tin-plated
Metal surface terminal point (top layer)
Tin (5 - 7 µm Sn)
Metal surface terminal point (middle layer)
Nickel (2 - 3 µm Ni)
Metal surface soldering area (top layer)
Tin (5 - 7 µm Sn)
Metal surface soldering area (middle layer)
Nickel (2 - 3 µm Ni)
Material data - housing
Housing color
green (6021)
Insulating material
PA
Insulating material group
I
CTI according to IEC 60112
600
Flammability rating according to UL 94
V0
Glow wire flammability index GWFI according to EN 60695-2-12
850
Glow wire ignition temperature GWIT according to EN 60695-2-13
775
Temperature for the ball pressure test according to EN 60695-10-2
125
Dimensions for the product
Dimensional drawing
----
Caption
Schematische Abbildung - weitere Details siehe Produktfamilienzeichnung im Download Center
Length [ l ]
36.8 mm
Width [ w ]
10
Height [ h ]
33.3 mm
Height (without solder pin)
29
Solder pin [P]
4.3 mm
Pin dimensions
1 x 0.9 mm
Dimensions for PCB design
Hole diameter
1.4 mm
Packaging information
Type of packaging
packed in cardboard
Pieces per package
50
Denomination packing units
Pcs.
Ambient conditions
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Ambient temperature (assembly)
-5 °C ... 100 °C
Ambient temperature (operation)
-40 °C ... 100 °C (Depending on the current carrying capacity/derating curve)
Termination and connection method
Test for conductor damage and slackening
IEC 60998-2-1:1990-04
Test for conductor damage and slackening
Test passed
Pull-out test
Pull-out test
IEC 60998-2-1:1990-04
Conductor cross section / conductor type / tensile force
0.5 mm² / solid / > 30 N
Conductor cross section / conductor type / tensile force
0.5 mm² / flexible / > 30 N
Conductor cross section / conductor type / tensile force
16 mm² / solid / > 100 N
Conductor cross section / conductor type / tensile force
10 mm² / flexible / > 90 N
Mechanical tests according to standard
Test specification
IEC 60998-2-1 (in parts)
Electrical tests
Rated current
76
Conductor cross section
10
Air clearances and creepage distances
Clearances and creepage distances
IEC 60664-1:2007-04
Specification
IEC 60664-1:2007-04
Minimum clearance - inhomogeneous field (III/3)
3
Minimum clearance - inhomogeneous field (III/2)
3
Minimum clearance - inhomogeneous field (II/2)
3
Minimum creepage distance value (III/3)
3.2 mm
Minimum creepage distance value (III/2)
3
Minimum creepage distance value (II/2)
3.2 mm
Temperature-rise test
Specification
IEC 60998-2-1:1990-04
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Current carrying capacity / derating curves
Diagram
----
Caption
Type: KDS 10Test following DIN EN 60512-5-2:2003-01Reduction factor = 1No. of positions: 5
Vibration test
Specification
IEC 60068-2-6:1995-03
Frequency
10 - 150 - 10 Hz
Sweep speed
1
Amplitude
0.35 mm (10 - 60.1 Hz)
Acceleration
5 g (60.1 - 150 Hz)
Test duration per axis
2.5 h
Insulation resistance
Result
Test passed
Insulation resistance, neighboring positions
109
Glow-wire test
Temperature
850
Time of exposure
5
Mechanical strength/tumbling barrel test
Number of drop cycles
50
Standards and Regulations
Connection in acc. with standard
EN-VDE
Connection in acc. with standard
CSA
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values