Product Description:
Installation ground terminal block, Screw connection, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 8.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

GTIN
: 04046356817639
Series
: UTI 6-PE/L/N
Type
: Installatie-aardklem
Key Features
- Instal.ation ground terminal block
- Screw connection
- cross section: 0.2 mm² - 10 mm²
- AWG: 24 - 8
- width: 8.2 mm
- color: gray
- mounting type: NS 35/7
- NS 35/15
Advantages
• The installation terminal block features a particularly low-profile design and is suitable for wiring in flat installation distributors
Training Data Goes here
General
Number of levels
3
Number of connections
5
Nominal cross section
6
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
6
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.31 W (the value is multiplied when connecting multiple levels)
Nominal current IN
38 A (with 6 mm² conductor cross section)
Maximum load current
47 A (with 10 mm² conductor cross section)
Nominal voltage UN
400 V (phase conductor/phase conductor)
Nominal voltage UN
250 V (phase conductor/PE)
Nominal voltage UN
250 V (phase conductor/N)
Open side panel
Yes
Dimensions
Width
8.2 mm
End cover width
2.2 mm
Length
95
Height NS 35/7,5
51.5 mm
Height NS 35/15
59
Connection data
Note
Please observe the current carrying capacity of the DIN rails.
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
10
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
10
Conductor cross section AWG min.
24
Conductor cross section AWG max.
8
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
6
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
6
2 conductors with same cross section, solid min.
0.2 mm²
2 conductors with same cross section, solid max.
2.5 mm²
2 conductors with same cross section, stranded min.
0.2 mm²
2 conductors with same cross section, stranded max.
2.5 mm²
Connection method
Screw connection
Stripping length
9
Internal cylindrical gage
A5
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years