Product Description:
Installation ground terminal block, Screw connection, cross section: 0.75 mm² - 35 mm², AWG: 18 - 2, width: 15 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15

GTIN
: 04046356347273
Series
: UTI 35-PE
Type
: Installatie-aardklem
Key Features
- Instal.ation ground terminal block
- Screw connection
- cross section: 0.75 mm² - 35 mm²
- AWG: 18 - 2
- width: 15 mm
- color: green-yellow
- mounting type: NS 35/7
- NS 35/15
Advantages
• The asymmetrical arrangement of the terminal blocks on the DIN rail enables the neutral busbar to be routed past the terminal blocks
• The installation terminal block features a particularly low-profile design and is suitable for wiring in flat installation distributors
Training Data Goes here
General
Number of levels
1
Number of connections
2
Potentials
2
Nominal cross section
35
Color
green-yellow
Insulating material
PA
Flammability rating according to UL 94
V2
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Nominal current IN
125
Nominal voltage UN
800
Open side panel
No
Terminal block mounting
2.5 Nm ... 3 Nm (PE foot with mounting screw, M5)
Dimensions
Width
15
Length
55
Height NS 35/7,5
51
Height NS 35/15
58.5 mm
Connection data
Note
Please observe the current carrying capacity of the DIN rails.
Connection method
Screw connection
Screw thread
M6
Stripping length
16
Tightening torque, min
3.2 Nm
Tightening torque max
3.7 Nm
Connection in acc. with standard
IEC 60947-7-2
Conductor cross section solid min.
0.75 mm²
Conductor cross section solid max.
35
Conductor cross section AWG min.
18
Conductor cross section AWG max.
2
Conductor cross section flexible min.
0.75 mm²
Conductor cross section flexible max.
35
Min. AWG conductor cross section, flexible
18
Max. AWG conductor cross section, flexible
2
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
35
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.75 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
35
2 conductors with same cross section, solid min.
0.75 mm²
2 conductors with same cross section, solid max.
10
2 conductors with same cross section, stranded min.
0.75 mm²
2 conductors with same cross section, stranded max.
10
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.75 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
6
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.75 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
10
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 125°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.A*30.B.01742
EAC RU C-DE.BL08.B.00534