Product Description:
Inline, Block IO, Ethernet, RJ45 jack, Digital inputs: 32, 24 V DC, connection method: 3-wire, Digital outputs: 16, 24 V DC, 500 mA, connection method: 2-wire, degree of protection: IP20, including Inline connector

GTIN
: 04046356012324
Series
: ILB ETH 24 DI16 DIO16-2TX
Type
: I/O-moduul
Key Features
- Inline
- Block IO
- Ethernet
- RJ45 jack
- Digital inputs: 32
- 24 V DC
- connection method: 3-wire
- Digital outputs: 16
- 24 V DC
- 500 mA
- connection method: 2-wire
- degree of protection: IP20
- including Inline connector
Advantages
• HTTP (web server)
• SNMP
• DDI
• BootP
• Modbus/TCP
Training Data Goes here
Dimensions
Dimensional drawing
----
Width
156
Height
141
Depth
57
Note on dimensions
Specfications with connectors
Ambient conditions
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
max. 85 % (non-condensing)
Air pressure (operation)
80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (up to 3500 m above sea level)
Degree of protection
IP20
General
Mounting type
DIN rail
Net weight
500
Note on weight specifications
with connectors
Diagnostics messages
Short-circuit or overload of the digital outputs Message in the diagnostics register
Diagnostics messages
Short-circuit, sensor supply Message in the diagnostics register
Diagnostics messages
Undervoltage Power supply for sensors Message in the diagnostics register
Mounting type
NS 35/7,5
Interfaces
Designation
Ethernet
Number
2
Connection method
RJ45 jack
Transmission speed
10/100 Mbps (with auto negotiation)
Transmission physics
Copper
Digital inputs
Input name
Digital inputs
Description of the input
16 fixed and 16 freely selectable
Connection method
Spring-cage connection
Connection technology
3-conductor
Number of inputs
32
Typical response time
approx. 500 µs
Protective circuit
Short-circuit protection, overload protection of the sensor supply
Nominal input voltage UIN
24
Nominal input current at UIN
typ. 5 mA
Delay at signal change from 0 to 1
500
Digital outputs
Output name
Digital outputs
Connection technology
2-conductor
Number of outputs
16
Protective circuit
Short-circuit and overload protection
Nominal output voltage
24
Electrical isolation
Test section
I/O / Logic 500 V AC 50 Hz 1 min.
Test section
I/O area / FE 500 V AC 50 Hz 1 min.
Test section
Logic / FE 500 V AC 50 Hz 1 min.
Standards and Regulations
Noise emission
Industrial environment
Mechanical tests
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Mechanical tests
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 25g
Connection in acc. with standard
CUL
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values