Product Description:
High-current terminal block, nom. voltage: 1500 V, nominal current: 232 A, connection method: Screw connection, number of connections: 2, cross section: 25 mm² - 95 mm², AWG: 4 - 3/0, width: 25 mm, height: 90 mm, color: blue, mounting type: NS 35/15, NS 32

GTIN
: 04055626136097
Series
: UKH 95 1500V BU
Type
: Klem voor hoge stromen
Key Features
- High-current terminal block
- nom. voltage: 1500 V
- nominal current: 232 A
- connection method: Screw connection
- number of connections: 2
- cross section: 25 mm² - 95 mm²
- AWG: 4 - 3/0
- width: 25 mm
- height: 90 mm
- color: blue
- mounting type: NS 35/15
- NS 32
Advantages
• Reliable cable connection is ensured by three-point centering of the conductor in the prismatic sleeve base
• Screw locking by means of spring-loaded elements in the clamping part
• Low contact resistance of the contact surface due to ribbing
Training Data Goes here
General
Number of levels
1
Number of connections
2
Potentials
1
Nominal cross section
95
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
7.54 W
Maximum load current
232
Nominal current IN
232
Nominal voltage UN
1500
Open side panel
No
Shock protection test specification
DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection
guaranteed
Result of surge voltage test
Test passed
Surge voltage test setpoint
14.8 kV
Power frequency withstand voltage setpoint
3.82 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)
Test passed
Result of flexion and pull-out test
Test passed
Bending test rotation speed
10
Bending test turns
135
Bending test conductor cross section/weight
25 mm² / 4.5 kg
Bending test conductor cross section/weight
35 mm² / 6.8 kg
Tensile test result
Test passed
Conductor cross section tensile test
25
Tractive force setpoint
135
Conductor cross section tensile test
35
Tractive force setpoint
190
Conductor cross section tensile test
95
Tractive force setpoint
351
Result of tight fit on support
Test passed
Tight fit on carrier
NS 32/NS 35
Result of voltage-drop test
Test passed
Requirements, voltage drop
U1 ≤ 3,2 mVU2 ≤ 1,5 x U1dT ≤ 45 K
Result of temperature-rise test
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Short circuit stability result
Test passed
Conductor cross section short circuit testing
95
Short-time current
11.4 kA
Result of thermal test
Test passed
Proof of thermal characteristics (needle flame) effective duration
30
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
25
Length
85.5 mm
Height
90
Height NS 35/15
97.5 mm
Height NS 32
95
Connection data
Note
Screws with hexagonal socket
Connection method
Screw connection
Screw thread
M8
Stripping length
33
Tightening torque, min
15
Tightening torque max
20
Connection in acc. with standard
IEC 60947-7-1
Note
Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
Conductor cross section solid min.
25
Conductor cross section solid max.
95
Conductor cross section AWG min.
4
Conductor cross section AWG max.
3/0
Conductor cross section flexible min.
35
Conductor cross section flexible max.
95
Min. AWG conductor cross section, flexible
2
Max. AWG conductor cross section, flexible
3/0
Conductor cross section flexible, with ferrule without plastic sleeve min.
35
Conductor cross section flexible, with ferrule without plastic sleeve max.
95
Conductor cross section flexible, with ferrule with plastic sleeve min.
35
Conductor cross section flexible, with ferrule with plastic sleeve max.
95
Cross section with insertion bridge, solid max.
95
Cross section with insertion bridge, stranded max.
70
2 conductors with same cross section, solid min.
25
2 conductors with same cross section, solid max.
35
2 conductors with same cross section, stranded min.
25
2 conductors with same cross section, stranded max.
35
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
16
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
35
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 125°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.AI30.B.01102
EAC RU C-DE.BL08.B.00534