
Product Description:
High-current terminal block, Blocked, nom. voltage: 1000 V, nominal current: 125 A, connection method: Power-Turn connection, number of connections: 6, number of positions: 3, cross section: 2.5 mm² - 35 mm², AWG: 12 - 2, width: 48 mm, color: gray, mounting type: NS 35/15

GTIN
: 04046356869546
Series
: PTPOWER 35-3L
Type
: Klem voor hoge stromen
Key Features
- High-current terminal block
- Blocked
- nom. voltage: 1000 V
- nominal current: 125 A
- connection method: Power-Turn connection
- number of connections: 6
- number of positions: 3
- cross section: 2.5 mm² - 35 mm²
- AWG: 12 - 2
- width: 48 mm
- color: gray
- mounting type: NS 35/15
Advantages
• Quick and easy connection is now also possible for large conductors with the high-current terminal block
• The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors
• The compact design and front connection enable wiring in a confined space
• In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
Training Data Goes here
General
Number of positions
3
Number of levels
1
Number of connections
6
Potentials
3
Nominal cross section
35
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
4.06 W
Maximum load current
125 A (with 35 mm² conductor cross section)
Nominal current IN
125
Nominal voltage UN
1000
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
48
Length
91.6 mm
Height NS 35/7,5
69.8 mm
Height NS 35/15
77.3 mm
Connection data
Connection
1
Connection method
Power-Turn connection
Stripping length
25
Conductor cross section solid min.
2.5 mm²
Conductor cross section solid max.
35
Conductor cross section AWG min.
12
Conductor cross section AWG max.
2
Conductor cross section flexible min.
2.5 mm²
Conductor cross section flexible max.
35
Min. AWG conductor cross section, flexible
12
Max. AWG conductor cross section, flexible
2
Conductor cross section flexible, with ferrule without plastic sleeve min.
2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
35
Conductor cross section flexible, with ferrule with plastic sleeve min.
2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
35
Connection cross sections directly pluggable
2.5 mm² 35 mm² 12 2
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values