Ground modular terminal block, connection method: Screw connection, number of connections: 2, number of positions: 1, cross section: 16 mm² - 50 mm², AWG: 6 - 1/0, width: 20 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15, NS 32
GTIN
: 04017918002282
Series
: USLKG 50
Type
: Aardklem
Key Features
- Ground m.dular terminal block
- connection method: Screw connection
- number of connections: 2
- number of positions: 1
- cross section: 16 mm² - 50 mm²
- AWG: 6 - 1/0
- width: 20 mm
- color: green-yellow
- mounting type: NS 35/7
- NS 35/15
- NS 32
Advantages
• Reliable cable connection is ensured by three-point centering of the conductor in the prismatic sleeve base
• Low contact resistance of the contact surface due to ribbing
• Screw locking by means of spring-loaded elements in the clamping part
Training Data Goes here
General
Number of positions
1
Number of levels
1
Number of connections
2
Nominal cross section
50
Color
green-yellow
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
4.73 W
Open side panel
No
Terminal block mounting
6 Nm ... 8 Nm (PE foot with mounting screw, M6)
Relative insulation material temperature index (Elec., UL 746 B)
125
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125
Dimensions
Width
20
Length
70.5 mm
Height NS 35/15
83.5 mm
Height NS 32
81
Connection data
Note
Please observe the current carrying capacity of the DIN rails.
Connection method
Screw connection
Screw thread
M6
Stripping length
24
Tightening torque, min
6
Tightening torque max
8
Connection in acc. with standard
IEC 60947-7-2
Conductor cross section solid min.
16
Conductor cross section solid max.
50
Conductor cross section AWG min.
6
Conductor cross section AWG max.
1/0
Conductor cross section flexible min.
25
Conductor cross section flexible max.
50
Min. AWG conductor cross section, flexible
3
Max. AWG conductor cross section, flexible
1/0
Conductor cross section flexible, with ferrule without plastic sleeve min.
25
Conductor cross section flexible, with ferrule without plastic sleeve max.
50
Conductor cross section flexible, with ferrule with plastic sleeve min.
25
Conductor cross section flexible, with ferrule with plastic sleeve max.
50
2 conductors with same cross section, solid min.
10
2 conductors with same cross section, solid max.
16
2 conductors with same cross section, stranded min.
10
2 conductors with same cross section, stranded max.
16
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
10
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
16
Connection in acc. with standard
IEC/EN 60079-7
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 125°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CSA
Environmental Product Compliance
REACh SVHC
4-Nonylphenol, ethoxylated
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years