Ground modular terminal block, connection method: Screw connection, number of connections: 2, number of positions: 1, cross section: 0.5 mm² - 16 mm², AWG: 20 - 6, width: 10.2 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15, NS 32
GTIN
: 04017918002251
Series
: USLKG 16
Type
: Aardklem
Key Features
- Ground m.dular terminal block
- connection method: Screw connection
- number of connections: 2
- number of positions: 1
- cross section: 0.5 mm² - 16 mm²
- AWG: 20 - 6
- width: 10.2 mm
- color: green-yellow
- mounting type: NS 35/7
- NS 35/15
- NS 32
Training Data Goes here
General
Number of positions
1
Number of levels
1
Number of connections
2
Color
green-yellow
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Open side panel
No
Terminal block mounting
1.5 Nm ... 1.8 Nm (PE foot with mounting screw, M4)
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
10.2 mm
Length
42.5 mm
Height NS 35/7,5
54
Height NS 35/15
61.5 mm
Height NS 32
59
Connection data
Note
Please observe the current carrying capacity of the DIN rails.
Connection method
Screw connection
Screw thread
M4
Stripping length
11
Tightening torque, min
1.5 Nm
Tightening torque max
1.8 Nm
Connection in acc. with standard
IEC 60947-7-2
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
16
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10
Min. AWG conductor cross section, flexible
20
Max. AWG conductor cross section, flexible
8
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
10
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
10
2 conductors with same cross section, solid min.
0.5 mm²
2 conductors with same cross section, solid max.
4
2 conductors with same cross section, stranded min.
0.5 mm²
2 conductors with same cross section, stranded max.
4
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
6
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
4
Connection in acc. with standard
UL
Conductor cross section AWG min.
24
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CSA
Environmental Product Compliance
REACh SVHC
4-Nonylphenol, ethoxylated
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values