Protective conductor universal terminal block with bolt connection, cross section: 0.1 - 6 mm², width: 11 mm, color: green-yellow, special version for DIN rails NS 35/15-2,3, and NS 35/15-AL
GTIN
: 04017918254100
Series
: OTTA 6-PE-1
Type
: Aardklem
Key Features
- Prot.ctive conductor universal terminal block with bolt connection
- cross section: 0.1 - 6 mm²
- width: 11 mm
- color: green-yellow
- special version for DIN rails NS 35/15-2
- NS 35/15-AL
Training Data Goes here
General
Number of levels
1
Number of connections
2
Color
green-yellow
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
11
End cover width
1.5 mm
Length
43.5 mm
Height NS 35/15
59.5 mm
Connection data
Note
Please observe the current carrying capacity of the DIN rails.
Connection
1
Connection method
Bolt connection
Stripping length
The stripping length depends on the specification provided by the cable lug manufacturer.
Connection in acc. with standard
IEC 60947-7-2
Cable lug connection according to standard
DIN 46234:1980-03
Min. cross section for cable lug connection
0.1 mm²
Max. cross section for cable lug connection
6
AWG min
24
AWG max
10
Hole diameter, min.
4.3 mm
Cable lug width, max.
9.6 mm
Bolt diameter
4
Screw thread
M4
Tightening torque, min
1.5 Nm
Tightening torque max
1.8 Nm
Cable lug connection according to standard
DIN 46237:1970-07
Min. cross section for cable lug connection
0.5 mm²
Max. cross section for cable lug connection
2.5 mm²
AWG min
20
AWG max
14
Cable lug connection according to standard
DIN 46234/DIN 46237
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
DIN 46234/DIN 46237
Environmental Product Compliance
REACh SVHC
4-Nonylphenol, ethoxylated
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years