Product Description:
Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.14 mm²- 6 mm², AWG: 26 - 10, nominal current: 6.3 A, nom. voltage: 500 V, width: 6.2 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5, NS 35/15, color: blue

GTIN
: 04046356623377
Series
: UT 4-HESI (5X20) BU
Type
: Zekeringsaansluitklem
Key Features
- Fuse modu.ar terminal block
- fuse type: Glass / ceramics / ...
- connection method: Screw connection
- cross section: 0.14 mm²- 6 mm²
- AWG: 26 - 10
- nominal current: 6.3 A
- nom. voltage: 500 V
- width: 6.2 mm
- fuse type: G / 5 x 20
- mounting type: NS 35/7
- NS 35/15
- color: blue
Training Data Goes here
General
Number of levels
1
Number of connections
2
Nominal cross section
4
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V0
Maximum power dissipation for nominal condition
1.6 W
Rated surge voltage
6
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation
max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
Maximum power dissipation
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
Maximum power dissipation
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
Maximum power dissipation
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
Connection in acc. with standard
IEC 60947-7-3
Maximum load current
6.3 A (the current is determined by the fuse used)
Nominal current IN
6.3 A
Nominal voltage UN
500 V (The voltage is determined by the fuse or selected LED display)
Fuse
G / 5 x 20
Fuse type
Glass / ceramics / ...
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
6.2 mm
Length
57.8 mm
Height NS 35/7,5
73
Height NS 35/15
80.5 mm
Connection data
Conductor cross section solid min.
0.14 mm²
Conductor cross section solid max.
6
Conductor cross section flexible min.
0.14 mm²
Conductor cross section flexible max.
6
Conductor cross section AWG min.
26
Conductor cross section AWG max.
10
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
4
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.14 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
4
2 conductors with same cross section, solid min.
0.14 mm²
2 conductors with same cross section, solid max.
1.5 mm²
2 conductors with same cross section, stranded min.
0.14 mm²
2 conductors with same cross section, stranded max.
1.5 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.14 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
1.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
2.5 mm²
Connection method
Screw connection
Stripping length
9
Internal cylindrical gage
A4
Screw thread
M3
Tightening torque, min
0.6 Nm
Tightening torque max
0.8 Nm
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years
There is no accessory available for this product.