Product Description:
Fuse terminal block for cartridge fuse inserts 5 x 20 and 5 x 25, cross section: 0.2 - 4 mm², width: 8.2 mm, color: black

GTIN
: 04017918092856
Series
: UK-SI
Type
: Zekeringsaansluitklem
Key Features
- Fuse terminal block for cartridge fuse inserts 5 x 20 and 5 x 25
- cross section: 0.2 - 4 mm²
- width: 8.2 mm
- color: black
Training Data Goes here
General
Number of levels
1
Number of connections
2
Nominal cross section
4
Color
black
Insulating material
PA
Flammability rating according to UL 94
V0
Maximum power dissipation for nominal condition
1.02 W
Rated surge voltage
4
Rated operating voltage
250
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Connection in acc. with standard
IEC 60947-7-3
Maximum load current
6.3 A (is determined by the fuse used)
Nominal current IN
6.3 A
Nominal voltage UN
400 V (As a fuse terminal block)
Nominal voltage UN
400 V (As a disconnect terminal block)
Fuse
G / 5 x 20 / 5 x 25
Fuse type
Glass / ceramics / ...
Open side panel
No
Shock protection test specification
DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection
guaranteed
Finger protection
guaranteed
Note
During the replacement of the fuse-link the safety from finger-touch is not ensured, without additional measures.The safety from finger-touch is ensured with inserted fuse-link.
Result of surge voltage test
Test passed
Surge voltage test setpoint
4.8 kV
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
1.5 kV
Result of tight fit on support
Test passed
Contact resistance
Test passed
Compatibitity between modular fuse terminal block and fuse insert
Test passed
Actuatiing forces on plug in or lever in fuse insert carriers
Test passed
Result of the test for mechanical stability of terminal points (5 x conductor connection)
Test passed
Result of flexion and pull-out test
Test passed
Bending test rotation speed
10
Bending test turns
135
Bending test conductor cross section/weight
0.2 mm² / 0.2 kg
Bending test conductor cross section/weight
4 mm² / 0.9 kg
Testing the rated value of the power dissipation (overload and short circuit Protection)
Test passed
Testing the rated value of the power dissipation (exclusively short circuit protection)
Test passed
Result of temperature-rise test
Test passed
Result of thermal test
Test passed
Oscillation, broadband noise test result
Test passed
Test specification, oscillation, broadband noise
DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum
Service life test category 1, class B, body mounted
Test frequency
f1 = 5 Hz to f2 = 150 Hz
ASD level
1.857 (m/s2)2/Hz
Acceleration
0,8 g
Test duration per axis
5
Test directions
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
DIN EN 50155 (VDE 0115-200):2008-03
Shock form
Half-sine
Acceleration
5g
Shock duration
30
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
8.2 mm
Length
59.5 mm
Height NS 35/7,5
58
Height NS 35/15
65.5 mm
Height NS 32
63
Connection data
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
4
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
4
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
4
Cross section with insertion bridge, solid max.
4
Cross section with insertion bridge, stranded max.
4
2 conductors with same cross section, solid min.
0.2 mm²
2 conductors with same cross section, solid max.
1.5 mm²
2 conductors with same cross section, stranded min.
0.2 mm²
2 conductors with same cross section, stranded max.
1.5 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.25 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
1.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
2.5 mm²
Connection method
Screw connection
Stripping length
9
Internal cylindrical gage
A4
Screw thread
M3
Tightening torque, min
0.6 Nm
Tightening torque max
0.8 Nm
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CSA
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years