Product Description:
Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Push-in connection, cross section: 0.2 mm²- 6 mm², AWG: 24 - 10, nominal current: 28 A, nom. voltage: 24 V, width: 6.2 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5, NS 35/15, color: black

GTIN
: 04055626380568
Series
: PTTB 4-HESILED 24 (5X20)
Type
: Zekeringsaansluitklem
Key Features
- Fuse modu.ar terminal block
- fuse type: Glass / ceramics / ...
- connection method: Push-in connection
- cross section: 0.2 mm²- 6 mm²
- AWG: 24 - 10
- nominal current: 28 A
- nom. voltage: 24 V
- width: 6.2 mm
- fuse type: G / 5 x 20
- mounting type: NS 35/7
- NS 35/15
- color: black
Advantages
• The easily accessible fuse inserts are easy to use or replace
• Convenient fuse testing, thanks to test points on both sides
• Quick identification of faulty fuses, thanks to LED status indicator
• In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
• The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors
• The compact design and front connection enable wiring in a confined space
Training Data Goes here
General
Note
The current is determined by the fuse used, the voltage by the light indicator.
Number of levels
2
Number of connections
4
Nominal cross section
4
Color
black
Insulating material
PA
Flammability rating according to UL 94
V0
Maximum power dissipation for nominal condition
1.02 W
Rated surge voltage
6
Rated operating voltage
24
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation
max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
Maximum power dissipation
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
Maximum power dissipation
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
Maximum power dissipation
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
LED voltage range
12 V AC/DC ... 30 V AC/DC
LED current range
0.31 mA ... 0.95 mA
Connection in acc. with standard
IEC 60947-7-1
Maximum load current
32 A (bei 6 mm² Leiterquerschnitt starr)
Nominal current IN
28
Nominal voltage UN
24
Connection in acc. with standard
IEC 60947-7-3
Maximum load current (upper level)
6.3 A (the current is determined by the fuse used)
Nominal current IN (upper level)
6.3 A
Fuse
G / 5 x 20
Fuse type
Glass / ceramics / ...
Open side panel
No
Shock protection test specification
DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection
guaranteed
Finger protection
guaranteed
Note
Swing the locking lever to its final position before replacing the fuse.
Result of surge voltage test
Test passed
Surge voltage test setpoint
4
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
1.5 kV
Result of tight fit on support
Test passed
Contact resistance
Test passed
Compatibitity between modular fuse terminal block and fuse insert
Test passed
Actuatiing forces on plug in or lever in fuse insert carriers
Test passed
Result of the test for mechanical stability of terminal points (5 x conductor connection)
Test passed
Result of flexion and pull-out test
Test passed
Bending test rotation speed
10
Bending test turns
135
Bending test conductor cross section/weight
0.2 mm² / 0.2 kg
Bending test conductor cross section/weight
4 mm² / 0.9 kg
Bending test conductor cross section/weight
6 mm² / 1.4 kg
Testing the rated value of the power dissipation (overload and short circuit Protection)
Test passed
Testing the rated value of the power dissipation (exclusively short circuit protection)
Test passed
Result of temperature-rise test
Test passed
Result of aging test
Test passed
Temperature cycles
192
Result of thermal test
Test passed
Oscillation, broadband noise test result
Test passed
Test specification, oscillation, broadband noise
DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum
Service life test category 1, class B, body mounted
Test frequency
f1 = 5 Hz to f2 = 150 Hz
ASD level
0.964 (m/s2)2/Hz
Acceleration
0.58 g
Test duration per axis
5
Test directions
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
DIN EN 50155 (VDE 0115-200):2008-03
Shock form
Half-sine
Acceleration
5g
Shock duration
30
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
6.2 mm
End cover width
2.2 mm
Length
102.9 mm
Height NS 35/7,5
75.5 mm
Height NS 35/15
83
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Connection data
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
6
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
6
Conductor cross section AWG min.
24
Conductor cross section AWG max.
10
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
4
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
4
Connection method
Push-in connection
Stripping length
10 mm ... 12 mm
Internal cylindrical gage
A4
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values