Product Description:
Feed-through terminal block, nom. voltage: 500 V, nominal current: 24 A, connection method: Screw connection, number of connections: 4, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, width: 5.2 mm, color: red, mounting type: NS 35/7,5, NS 35/15, NS 32

GTIN
: 04046356460804
Series
: UDK 3 RD
Type
: Aansluitklem
Key Features
- Feed-thro.gh terminal block
- nom. voltage: 500 V
- nominal current: 24 A
- connection method: Screw connection
- number of connections: 4
- cross section: 0.2 mm² - 4 mm²
- AWG: 24 - 12
- width: 5.2 mm
- color: red
- mounting type: NS 35/7
- NS 35/15
- NS 32
Advantages
• Two connection points on each side to accommodate several conductors
• Double bridge shaft enables individual potential distribution and supply
Training Data Goes here
General
Number of levels
2
Number of connections
4
Potentials
1
Nominal cross section
2.5 mm²
Color
red
Insulating material
PA
Flammability rating according to UL 94
V2
Rated surge voltage
6
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
0.77 W (the value is multiplied when connecting multiple levels)
Maximum load current
32 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal current IN
24 A (with 4 mm² conductor cross section)
Nominal voltage UN
500
Open side panel
Yes
Shock protection test specification
IEC 60529:2001-02
Back of the hand protection
guaranteed
Finger protection
guaranteed
Result of surge voltage test
Test passed
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
1.89 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)
Test passed
Result of flexion and pull-out test
Test passed
Bending test rotation speed
10
Bending test turns
135
Bending test conductor cross section/weight
0.2 mm² / 0.2 kg
Bending test conductor cross section/weight
2.5 mm² / 0.7 kg
Tensile test result
Test passed
Result of tight fit on support
Test passed
Tight fit on carrier
NS 32/NS 35
Setpoint
1
Result of voltage-drop test
Test passed
Result of temperature-rise test
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Short circuit stability result
Test passed
Conductor cross section short circuit testing
2.5 mm²
Short-time current
0.3 kA
Conductor cross section short circuit testing
4
Short-time current
0.48 kA
Result of thermal test
Test passed
Proof of thermal characteristics (needle flame) effective duration
30
Dimensions
Width
5.2 mm
End cover width
1.5 mm
Length
63.5 mm
Height NS 35/7,5
47
Height NS 35/15
54.5 mm
Height NS 32
52
Connection data
Connection
1
Connection method
Screw connection
Screw thread
M3
Stripping length
8
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Min. AWG conductor cross section, flexible
24
Max. AWG conductor cross section, flexible
14
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
1.5 mm²
Cross section with insertion bridge, solid max.
2.5 mm²
Cross section with insertion bridge, stranded max.
2.5 mm²
2 conductors with same cross section, solid min.
0.2 mm²
2 conductors with same cross section, solid max.
1
2 conductors with same cross section, stranded min.
0.2 mm²
2 conductors with same cross section, stranded max.
1.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
1
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.25 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
1.5 mm²
Internal cylindrical gage
A3
Standards and Regulations
Connection in acc. with standard
CSA
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years