Feed-through terminal block with bolt connection technology and transparent safety contact hood, cross section: 0.1 - 6 mm², AWG: 26 - 10, width 16.3 mm, color: blue

GTIN
: 04046356425148
Series
: RTO 5-TC BU
Type
: Aansluitklem
Key Features
- Feed-through terminal block with bolt connection technology and transparent safety contact hood
- cross section: 0.1 - 6 mm²
- AWG: 26 - 10
- width 16.3 mm
- color: blue
Advantages
• Four bridge shafts per terminal block
• Terminal point always freely accessible
• Easy bridging and potential distribution using the patented plug-in bridges from the CLIPLINE complete system
• The screws are secured against loosening by captive spring-loaded spacers
• Large-surface labeling options in the terminal center and above the terminal points
Training Data Goes here
General
Note
Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories).
Number of levels
1
Number of connections
2
Potentials
1
Nominal cross section
6
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.31 W
Maximum load current
41 A (with 6 mm² conductor cross section)
Nominal current IN
41
Nominal voltage UN
1000
Open side panel
Yes
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
16.3 mm
End cover width
2.2 mm
Length
66
Height NS 35/7,5
51
Height NS 35/15
58.5 mm
Connection data
Connection
1
Connection method
Bolt connection
Stripping length
The stripping length depends on the specification provided by the cable lug manufacturer.
Connection in acc. with standard
IEC 60947-7-1
Cable lug connection according to standard
DIN 46234:1980-03
Min. cross section for cable lug connection
0.5 mm²
Max. cross section for cable lug connection
6
AWG min
20
AWG max
10
Hole diameter, min.
5.3 mm
Cable lug width, max.
10
Bolt diameter
5
Screw thread
M5
Tightening torque, min
2.5 Nm
Tightening torque max
3
Cable lug connection according to standard
DIN 46237:1970-07
Min. cross section for cable lug connection
1
AWG min
16
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.A*30.B.01742