Product Description:
Feed-through terminal block, nom. voltage: 800 V, nominal current: 32 A, connection method: Push-in connection, number of connections: 2, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, height: 35.3 mm, color: orange, mounting type: NS 35/7,5, NS 35/15

GTIN
: 04046356731348
Series
: PT 4 OG
Type
: Aansluitklem
Key Features
- Feed-throu.h terminal block
- nom. voltage: 800 V
- nominal current: 32 A
- connection method: Push-in connection
- number of connections: 2
- cross section: 0.2 mm² - 6 mm²
- AWG: 24 - 10
- width: 6.2 mm
- height: 35.3 mm
- color: orange
- mounting type: NS 35/7
- NS 35/15
Advantages
• In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
• The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors
• The compact design and front connection enable wiring in a confined space
• Tested for railway applications
Training Data Goes here
General
Number of levels
1
Number of connections
2
Potentials
1
Nominal cross section
4
Color
orange
Insulating material
PA
Flammability rating according to UL 94
V0
Area of application
Railway industry
Area of application
Machine building
Area of application
Plant engineering
Area of application
Process industry
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.02 W
Maximum load current
36 A (with 6 mm² conductor cross section, rigid)
Nominal current IN
32
Nominal voltage UN
800
Open side panel
Yes
Dimensions
Width
6.2 mm
End cover width
2.2 mm
Length
56
Height
35.3 mm
Height NS 35/7,5
36.5 mm
Height NS 35/15
44
Connection data
Connection
1
Connection method
Push-in connection
Stripping length
10 mm ... 12 mm
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
6
Conductor cross section AWG min.
24
Conductor cross section AWG max.
10
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
6
Min. AWG conductor cross section, flexible
24
Max. AWG conductor cross section, flexible
12
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
4
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
4
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
1
Connection cross sections directly pluggable
0.5 mm² 6 mm²
Conductor cross section solid min.
0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.5 mm²
Internal cylindrical gage
A4
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CSA
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values