Product Description:
Ground disconnect terminal block with screw connection, voltage 24 ... 60 V AC/DC, current: 3.5 ... 8 mA, cross section: 0.5 ... 6 mm², width: 22.5 mm, color: gray

GTIN
: 04017918092924
Series
: GTF 76/ 48
Type
: Scheidingsklem
Key Features
- Ground disconnect terminal block with screw connection
- voltage 24 ... 60 V AC/DC
- current: 3.5 ... 8 mA
- cross section: 0.5 ... 6 mm²
- width: 22.5 mm
- color: gray
Advantages
• Once the disconnect slide has been opened to the "off" position, the red light indicates whether there is a ground fault in the control circuit
• When the disconnect slide is closed, switch position "on", the yellow light indicates grounded normal operation
Training Data Goes here
General
Number of levels
1
Number of connections
2
Nominal cross section
6
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
4
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.31 W
Nominal current IN
41
Maximum load current
57
Nominal voltage UN
24
Nominal voltage UN
60
Voltage LED
48
Current LED
2
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Length
64.5 mm
Width
22.5 mm
Height NS 35/7,5
54
Height NS 35/15
61.5 mm
Height NS 32
59
Connection data
Connection method
Screw connection
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
10
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
6
Conductor cross section AWG min.
20
Conductor cross section AWG max.
8
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
6
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
4
2 conductors with same cross section, solid min.
0.5 mm²
2 conductors with same cross section, solid max.
6
2 conductors with same cross section, stranded min.
0.5 mm²
2 conductors with same cross section, stranded max.
6
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
4
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
4
Stripping length
12
Internal cylindrical gage
A5
Screw thread
M4
Tightening torque, min
1.2 Nm
Tightening torque max
1.5 Nm
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CUL