Product Description:
Device terminal block, nom. voltage: 630 V, nominal current: 125 A, connection method: Screw connection, number of connections: 4, number of positions: 2, cross section: 0.75 mm² - 35 mm², AWG: 18 - 2, width: 34.8 mm, height: 44.9 mm, color: blue, mounting type: direct screw connection

GTIN
: 04046356482363
Series
: GE 35/2 BU
Type
: Apparatenklem
Key Features
- Device terminal block
- nom. voltage: 630 V
- nominal current: 125 A
- connection method: Screw connection
- number of connections: 4
- number of positions: 2
- cross section: 0.75 mm² - 35 mm²
- AWG: 18 - 2
- width: 34.8 mm
- height: 44.9 mm
- color: blue
- mounting type: direct screw connection
Advantages
• Mounting with two screws per block
• Touch-proof shock protection
Training Data Goes here
General
Number of positions
2
Number of levels
1
Number of connections
4
Potentials
2
Nominal cross section
35
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V2
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
4.06 W
Maximum load current
125 A (with 35 mm² conductor cross section)
Nominal current IN
125
Nominal voltage UN
630
Open side panel
No
Dimensions
Width
34.8 mm
Length
83.7 mm
Height
44.9 mm
Connection data
Note
Terminal point
Connection method
Screw connection
Screw thread
M6
Stripping length
16
Tightening torque, min
3.5 Nm
Tightening torque max
4
Connection in acc. with standard
IEC 60947-7-1/IEC 60998
Conductor cross section solid min.
0.75 mm²
Conductor cross section solid max.
35
Conductor cross section AWG min.
18
Conductor cross section AWG max.
2
Conductor cross section flexible min.
0.75 mm²
Conductor cross section flexible max.
35
Min. AWG conductor cross section, flexible
18
Max. AWG conductor cross section, flexible
2
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
35
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.75 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
35
2 conductors with same cross section, solid min.
0.75 mm²
2 conductors with same cross section, solid max.
10
2 conductors with same cross section, stranded min.
0.75 mm²
2 conductors with same cross section, stranded max.
10
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
0.75 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
6
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
0.75 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
10
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 125°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.BL08.B.00534
There is no accessory available for this product.