Product Description:
Device connector for front wall, SH, angled rotatable, for standard and SPEEDCON interlock, M23, No. of pos.: 8+4+PE, type of contact: Socket, Crimp connection, Axial O-ring, 4x Ø 3.2, flange dimensions: 28 mm x 28 mm

GTIN
: 04046356937085
Series
: SH-8ESS48AAC00S
Type
: Apparaatconnector voorwand
Key Features
- Device connector for front wall
- SH
- angled rotatable
- for standard and SPEEDCON interlock
- M23
- No. of pos.: 8+4+PE
- type of contact: Socket
- Crimp connection
- Axial O-ring
- 4x Ø 3.2
- flange dimensions: 28 mm x 28 mm
Advantages
• Easy connection, thanks to infinitely adjustable cable outlet direction up to 310°
• All housing can be fitted with pin or socket contacts
• A total of eight contacts are available for signal transmission
• Safe use in the field, thanks to high degree of protection
• Consistent EMC protection for reliable connection solutions in the industrial environment
Training Data Goes here
Temperature range
Temperature range
-40 °C ... 115 °C (see derating curve)
Standards and Regulations
Safety note
WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Safety note
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Safety note
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
Safety note
• The products are suitable for applications in plant, controller, and electrical device engineering.
Safety note
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
Safety note
• Assembled products may not be manipulated or improperly opened.
Safety note
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
Safety note
• When using the product in direct connection with third-party manufacturers, the user is responsible.
Safety note
• For operating voltages > 50 V AC, conductive connector housings must be grounded
Safety note
• Ensure that the protective or functional ground has been properly connected.
Safety note
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
Safety note
• Only use tools recommended by Phoenix Contact
Safety note
• The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
Safety note
• Operate the connector only when it is fully plugged in and interlocked.
Safety note
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
Safety note
• Observe the minimum bending radius of the cable. Lay the cable without twisting it.
Safety note
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Data of the insulating body
Note
Order information: Crimp contacts, 8 x Ø 1 mm, 5 x Ø 2 mm, order separately
Protection against electric shock
IEC 61984 and VDE 0623
Coding
N
Insulator material
PA 6.6
Insertion/withdrawal cycles mechanical
100
Contact connection method
Crimp connection
Type of contacts
Socket
Application
Hybrid
Number of positions
13
Contact diameter of power contacts
2
Litz wire cross section of power contacts min.
0.25 mm²
Litz wire cross section of power contacts max.
4
Rated current for power contacts
30
Rated surge voltage
6
Rated voltage (II/3) power contact
850 V DC
Rated voltage (III/3) power contact
630 V AC
Contact diameter of signal contacts
1
Litz wire cross section of signal contacts min.
0.06 mm²
Litz wire cross section of signal contacts max.
1
Nominal current per signal contact
8
Note
for max. connection cross section
Rated surge voltage
1.5 kV
Rated voltage (III/3) signal contact
50
Installation height
2000
Housing data
Note
The suitability for assembly must be checked when fully assigned with maximum wire cross sections.
Housing material
Turned parts: copper zinc alloy (CuZn), die-cast parts: zinc (GD-Zn)
Flange dimensions
28 mm x 28 mm
Type of locking
for standard and SPEEDCON interlock
Degree of protection (when plugged in)
IP67
Degree of protection (when plugged in)
IP68
Degree of protection (when plugged in)
IP69K
Thread type
M23
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years