Product Description:
DC charging cable, With vehicle charging connector and open cable end, Housing color black-gray, For charging electric vehicles (EV) with direct current (DC), For installation at charging stations for electromobility (EVSE), CCS type 2, Combined Charging System, IEC 62196-3, 125 A / 1000 V (DC), D-Line 1.0, “PHOENIX CONTACTâ€? logo, cable: 10 m, black, straight, NOTE: The cable length exceeds the normative specification of 10 m.

GTIN
: 04055626198255
Series
: EV-T2M4CC-DC125A-10M50ESBK00
Type
: DC-laadkabels
Key Features
- DC charging cable
- With vehicle charging connector and open cable end
- Housing color black-gray
- For charging electric vehicles with direct current
- For installation at charging stations for electromobility
- CCS type 2
- Combined Charging System
- IEC 62196-3
- 125 A / 1000 V
- D-Line 1.0
- “PHOENIX CONTACTâ€? logo
- cable: 10 m
- black
- straight
- NOTE: The cable length exceeds the normative specification of 10 m.
Advantages
• Consistent design of all Phoenix Contact Vehicle Connectors and Infrastructure Plugs
• Silver-plated surface of the power and signal contacts
• Certified in accordance with IATF 16949:2016 and ISO 9001:2015
• Convenient handling, thanks to the ergonomic handle and additional, rubber grip components
• Integrated temperature sensors for monitoring the temperature at the power contacts
Training Data Goes here
Product definition
Type
DC charging cable
Type
with vehicle charging connector and open cable end
Type
Housing color black-gray
Application
For charging electric vehicles (EV) with direct current (DC)
Application
for installation at charging stations for electromobility (EVSE)
Affixed logo
“PHOENIX CONTACT” logo
Design
D-Line 1.0
Standards/regulations
IEC 62196-3
Charging standard
CCS type 2
Charging standard
Combined Charging System
Charging mode
Mode 4
Normative cable length restrictions
NOTE: The cable length exceeds the normative specification of 10 m.
Normative cable length restrictions
Interference-free V2G communication in accordance with ISO 15118 is not guaranteed for cable lengths over 10 m (ISO IEC 15118-3, A.11.3, Table A.11).
Normative cable length restrictions
Cable management is required in certain regions if the cable length exceeds 5.0 m (Switzerland) or 7.5 m (USA) (IEC 61851-1).
Dimensions
Height
139 mm (Vehicle charging connector)
Width
75 mm (Vehicle charging connector)
Depth
267 mm (Vehicle charging connector)
Conductor length
10
Stripping length
140 mm ±10 mm
Ambient conditions
Ambient temperature (operation)
-30 °C ... 50 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Max. altitude
5000 m (above sea level)
Degree of protection
IP44 (plugged in; when plugged in and ready to operate, the degree of protection is only ensued if both plug-in components are original products from Phoenix Contact or suitable standard-compliant products)
Degree of protection
IP20 (when not plugged in, the required IP24 degree of protection must be ensured by other means, e.g., by a holder, see accessories)
Electrical properties
Maximum charging power
125
Number of power contacts
3 (PE, DC+, DC-)
Rated current of power contacts
125
Rated voltage for power contacts
1000
Number of signal contacts
2 (CP, PP)
Rated current for signal contacts
2
Rated voltage for signal contacts
30
Type of signal transmission
Pulse width modulation with modulated Powerline communication according to ISO/IEC 15118 / DIN SPEC 70121
Note on the connection method
Crimp connection, cannot be disconnected
Resistor coding
1500 Ω (between PE and PP)
Temperature monitoring
2x Pt 1000
Mechanical properties
Insertion/withdrawal cycles
> 10000
Insertion force
< 100 N
Withdrawal force
< 100 N
Design
Design line
Standard
Housing color
black
Mating face color
black
Color handle area
gray
Label
14.1 mm x 44.8 mm (customer logo on request)
Material
Housing material
Plastic
Material handle area
Soft plastic
Material mating face
Plastic
Flammability rating
V0
Material surface of contacts
Ag
Cable
Cable structure
2 x 50 mm² + 1 x 25 mm² + 3 x 2 x 0.75 mm²
Wiring standards/regulations
prEN 50620 / DIN EN 50620
Wiring class
Class 6
Wiring certifications
VDE-Reg. 8798
External cable diameter
28.1 mm ±0.5 mm
Type of conductor
straight
Cable resistance
≤ 0.00039 Ω/m (based on a power core, at an ambient temperature of 20°C)
Outer sheath, material
TPE-U
External sheath, color
black
Minimum bending radius
281 mm (10 x diameter)
Cable weight
max. 1620 kg/km
Temperature sensors
Type of sensor
Pt 1000
Standards/regulations
DIN EN 60751
Recommended measured current
1 mA (1 V at 0°C)
Tolerance at the sensor with the recommended measured current
±1K
Temperature range
-50 °C ... 130 °C
Temperature coefficient (TCR)
3850 ppm/K
Long-term stability (max. R0-Drift)
0.06 % (After 1000 hours at 130°C)
Shutdown temperature
90 °C equivalent to a Pt 1000 value of 1346.5 Ω
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 10;