Circular connectors (cable-side), Range of articles: PRC, Coupler connector, type: Can only be released with a tool, housing material: PPE, color: black, number of positions: 5, min. conductor cross section: 1.5 mm², max. conductor cross section: 6 mm², nom. voltage: 690 V AC, rated current: 35 A, Connection method: Screw connection, Type of contact: Socket, min. cable diameter: 8 mm, max. cable diameter: 12 mm

GTIN
: 04046356904223
Series
: PRC 5-FC-FS6 8-12
Type
: Koppelconnectoren
Key Features
- Circular connectors
- Range of articles: PRC
- Coupler connector
- type: Can only be released with a tool
- housing material: PPE
- color: black
- number of positions: 5
- min. conductor cross section: 1.5 mm²
- max. conductor cross section: 6 mm²
- nom. voltage: 690 V AC
- rated current: 35 A
- Connection method: Screw connection
- Type of contact: Socket
- min. cable diameter: 8 mm
- max. cable diameter: 12 mm
Advantages
• Up to 75% smaller in size than industrial connectors with the same rating
• Locking mechanism can be unlocked manually or using a tool
• Suitable for applications in atmospheres containing salt and in direct sunlight
• Ideal for indoor and outdoor use due to weatherproof materials
Training Data Goes here
General data
Number of positions
5
Protection class
II
Color
black
Locking type
Snap-in locking
Insertion/withdrawal cycles
100
Pull-out-force
175 N ± 50 N
Insertion force
40 N ±10 N
Degree of protection (when plugged in)
IP66 / IP68 (2m / 24h) / IP69K
Width
37.6 mm
Height
37.6 mm
Length
107.5 mm
Connection data
Rated current
35 A (With 6 mm² conductor cross section in accordance with IEC 61984)
Rated current
32 A (With 6 mm² conductor cross section in accordance with IEC 61535)
Rated current
21.4 A (With 6 mm² conductor cross section and 85 °C in accordance with 2 PfG 1915)
Rated current
30 A (With 6 mm²/AWG 10, in accordance with UL 2238)
Nominal voltage ATD
690 V AC (in accordance with IEC 61984)
Nominal voltage ATD
500 V AC (in accordance with IEC 61535/2 PfG 1915)
Nominal voltage ATD
600 V AC (In accordance with UL 2238)
Rated voltage (III/2)
690
Stripping length
12
Torque
max. 1 Nm (Contact screw)
Type of contact
Socket
Stripping length of the sheath
50
Conductor cross section flexible, with ferrule without plastic sleeve min.
1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
6
Conductor cross section flexible, with ferrule with plastic sleeve min.
1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
6
Conductor cross section solid min.
1.5 mm²
Conductor cross section solid max.
6
Conductor cross section flexible min.
4
Conductor cross section flexible max.
6
Type
Can only be released with a tool
Connection method
Screw connection
Degree of protection
IP66 / IP68 (2m / 24h) / IP69K
Stripping length of the individual wire
12 mm (Lay PE conductor 8 mm leading)
Overvoltage category
III
Insulating material group
I / CTI 600
Material data
Contact material
Cu alloy
Contact surface material
silver-plated
Contact carrier material
PPE
Housing material
PPE
Seal material
EPDM
O-ring material
EPDM
Cable seal material
EPDM
Cable gland material
PPE
Color of the housing part
black
Standards and Regulations
Halogen-free
yes
Flammability rating according to UL 94
V0
Safety note
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Safety note
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
Safety note
WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Safety note
• Assembled products may not be manipulated or improperly opened.
Safety note
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
Safety note
• When using the product in direct connection with third-party manufacturers, the user is responsible.
Safety note
• For operating voltages > 50 V AC, conductive connector housings must be grounded
Safety note
• Ensure that the protective or functional ground has been properly connected.
Safety note
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
Safety note
• Observe the corresponding technical data. You will find information:o On the product On the packing label In the supplied documentation Online at phoenixcontact.com/products under the product
Safety note
• Only use tools recommended by Phoenix Contact
Safety note
• The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
Safety note
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
Safety note
• Operate the connector only when it is fully plugged in.
Safety note
• Operate the connector only when it is fully plugged in and interlocked.
Safety note
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
Safety note
• Observe the minimum bending radius of the cable. Lay the cable without twisting it.
Safety note
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years