Product Description:
HEAVYCON male insert, K6/12 series, with 6 power (axial screw connection) and 12 control contacts (screw connection)

GTIN
: 04046356011495
Series
: HC-K 6/12-ESTS
Type
: Contactblok
Key Features
- HEAVYCON male insert
- K6/12 series
- with 6 power and 12 control contacts
Training Data Goes here
General
Note
For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench
Note
Connectors may be operated only when there is no load/voltage.
Note
The axial screw connection must be established using a 2 mm Allen key (for stranded conductors only)
Connection method
Axial screw connection (power contacts)
Connection method
Screw connection (control contacts)
Tightening torque
0.5 Nm ... 0.8 Nm (control contacts)
Tightening torque
1.5 Nm (Power contacts 2.5 ... 4 mm²)
Tightening torque
2 Nm (Power contacts 6 ... 8 mm²)
Torque
0.8 Nm ... 1.2 Nm (PE connection)
Torque
0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Screwdriver blade
0.5 x 3.5 mm (control contacts)
Degree of pollution
3
Overvoltage category
III
Number of positions
6+12+PE
No. of power contacts
6
No. of control contacts
12
Insertion/withdrawal cycles
≥ 500
Size
B16
Size
B32
Contact numbering
1 - 6
Conductor cross section
2.5 mm² ... 8 mm² (power contacts)
Conductor cross section
0.2 mm² ... 2.5 mm² (control contact)
Connection cross section AWG
12 ... 10 (power contacts)
Connection cross section AWG
24 ... 14 (control contacts)
Stripping length of the individual wire
8 mm +1 mm (Power contacts 6 ... 8 mm²)
Stripping length of the individual wire
10 mm (control contacts)
Stripping length of the individual wire
5 mm +1 mm (Power contacts 2.5 ... 4 mm²)
Wire diameter including insulation
6.1 mm (max., power contacts)
Assembly instructions
To ensure correct use, installation in housing with IP54 protection or better is required
Connection
Note regarding axial connection technology: Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructions Before assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C
Material data
Contact material
Cu alloy
Material of contact surface, power contact
Ag
Material of contact surface, control contact
Ag
Contact carrier material
PC
Electrical characteristics
Rated voltage for power contacts
230/400 V
Rated voltage (III/3)
690
Rated voltage (III/3)
230 V (Conductor-PE)
Rated voltage (III/3)
400 V (Signal contacts, conductor-conductor)
Rated surge voltage
8 kV (power contacts)
Rated surge voltage
4 kV (control contacts)
Rated current
40 A (power contacts)
Rated current
10 A (control contacts)
Standards and Regulations
Connection in acc. with standard
CSA
Flammability rating according to UL 94
V0
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years