Product Description:
Type 1 / Class I / B arrester (lightning current arrester) with encapsulated N-PE total spark gap, 1-channel. Housing width: 35 mm (2 Div.)

GTIN
: 04017918165390
Series
: FLT 100-260
Type
: Combi-afleider Type 1+2
Key Features
- Type 1 / Class I / B arrester with encapsulated N-PE total spark gap
- 1-channel
- Housing width: 35 mm
Advantages
• High discharge capacity
• 1-channel
Training Data Goes here
Dimensions
Height
89.8 mm
Width
35.8 mm
Depth
65.8 mm
Horizontal pitch
2
Ambient conditions
Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40 °C ... 85 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % ... 95 %
General
IEC test classification
I
IEC test classification
T1
EN type
T1
IEC power supply system
TT
IEC power supply system
TN-S
Mode of protection
N-PE
Mounting type
DIN rail: 35 mm
Color
jet black RAL 9005
Housing material
PBT
Degree of pollution
2
Flammability rating according to UL 94
V-0
Type
DIN rail module, one-piece
Number of positions
1
Surge protection fault message
none
Additional descriptions
Note
100 % lightning impulse sparkover voltage (1.2/50) µs ≤ 4.0 kV
Protective circuit
Nominal voltage UN
230/400 V AC (TN - only N-PE)
Nominal voltage UN
230/400 V AC (TT - only N-PE)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
260 V AC
Rated load current IL
80
Residual current IPE
≤ 0.1 mA
Standby power consumption PC
≤ 26 mVA
Nominal discharge current In (8/20) µs
100
Impulse discharge current (10/350) µs, charge
50
Impulse discharge current (10/350) µs, specific energy
2.5 MJ/Ω
Impulse discharge current (10/350) µs, peak value limp
100
Follow current interrupt rating Ifi
100 A (260 V AC)
Voltage protection level Up
≤ 5.5 kV
Front of wave sparkover voltage at 6 kV (1.2/50) µs
≤ 5.5 kV
TOV behavior at UT
1200 V AC (200 ms / withstand mode)
Response time tA
≤ 100 ns
Connection data
Connection method
Screw connection
Screw thread
M6
Tightening torque
8
Stripping length
14.5 mm
Conductor cross section flexible
16 mm² ... 35 mm²
Conductor cross section solid
10 mm² ... 50 mm²
Conductor cross section AWG
6 ... 1
Standards and Regulations
Standards/regulations
IEC 61643-11 2011
Standards/regulations
EN 61643-11 2012
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
EAC RU C-DE.*09.B.00169