
Product Description:
Cable connector, M23 PRO, straight, shielded: yes, ONECLICK fast locking system, M23, No. of pos.: 8+1, type of contact: Socket, Crimp connection, cable diameter range: 9 mm ... 15 mm

GTIN
: 04055626618067
Series
: M23-09S1N8A8004S
Type
: Kabelconnectoren
Key Features
- Cable connector
- M23 PRO
- straight
- shielded: yes
- ONECLICK fast locking system
- M23
- No. of pos.: 8+1
- type of contact: Socket
- Crimp connection
- cable diameter range: 9 mm ... 15 mm
Advantages
• Solutions with cross-manufacturer compatibility for standard and fast locking systems
• ONECLICK fast locking system with an optically, haptically, and acoustically clear locking position
• Reliable under the harshest conditions: cable connectors with vibration brake
• Modern, consistent design for highly convenient operation
• Easy, cost-effective cable assembly: uniform shielding of M17 to M40
Training Data Goes here
Temperature range
Temperature range
-40 °C ... 125 °C
Standards and Regulations
Safety note
WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Safety note
WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Safety note
WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
Safety note
The products are suitable for applications in plant, controller, and electrical device engineering.
Safety note
When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
Safety note
Assembled products may not be manipulated or improperly opened.
Safety note
Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
Safety note
When using the product in direct connection with third-party manufacturers, the user is responsible.
Safety note
For operating voltages > 50 V AC, conductive connector housings must be grounded
Safety note
Ensure that the protective or functional ground has been properly connected.
Safety note
VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
Safety note
Only use tools recommended by Phoenix Contact
Safety note
The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
Safety note
Operate the connector only when it is fully plugged in and interlocked.
Safety note
Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
Safety note
Observe the minimum bending radius of the cable. Lay the cable without twisting it.
Safety note
The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Data of the insulating body
Note
Order information: Order crimp contacts 8 x Ø 1 mm, 1 x Ø 2 mm separately
Coding
N
Insulator material
PA 6.6
Contact connection method
Crimp connection
Type of contacts
Socket
Application
Signal
Number of positions
9
Direction of rotation
Standard
Contact diameter of power contacts
2
Litz wire cross section of power contacts min.
0.5 mm²
Litz wire cross section of power contacts max.
2.5 mm²
Rated current for power contacts
20
Note
for max. connection cross section
Rated voltage
300
Rated surge voltage
2.5 kV
Overvoltage category
II
Degree of pollution
3
Contact diameter of signal contacts
1
Litz wire cross section of signal contacts min.
0.08 mm²
Litz wire cross section of signal contacts max.
1
Nominal current per signal contact
8
Rated voltage of signal contact
300
Installation height
2000
Housing data
Housing material
GD-Zn
Type of locking
ONECLICK fast locking system
Degree of protection (when plugged in)
IP66 / IP68 (2 m / 24 h)
Thread type
M23
Cable seal data
Cable diameter
9 mm ... 15 mm
Sealing material
FKM
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values