Product Description:
Feed-through terminal block with bolt connection method, cross section: 0.1 - 10 mm², AWG: 26 - 8, width 13 mm, color: gray

GTIN
: 04046356500333
Series
: RSC 5-F
Type
: Boutaansluitklem
Key Features
- Feed-through terminal block with bolt connection method
- cross section: 0.1 - 10 mm²
- AWG: 26 - 8
- width 13 mm
- color: gray
Advantages
• Large-surface, consistent external and center labeling
• Mounting on standard DIN rails or directly in control boxes
• Compact screw connection of ring and fork-type cable lugs
• Cover profile that can be snapped directly onto the terminal blocks provides touch-proof protection
• Screw nuts and current bars are latched in the insulating housing and cannot be removed
• The isolator bridge bar supports switchable cross connections; the bridge screw therefore has the function of a live contact
• Bridge shaft for potential distribution using standard screw bridges
Training Data Goes here
General
Number of levels
1
Number of connections
2
Potentials
1
Nominal cross section
10
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.82 W
Maximum load current
57 A (with 10 mm² conductor cross section)
Nominal current IN
57
Nominal voltage UN
800
Open side panel
Yes
Shock protection test specification
IEC 60529:2001-02
Back of the hand protection
guaranteed
Result of surge voltage test
Test passed
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
2
Result of the test for mechanical stability of terminal points (5 x conductor connection)
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Short circuit stability result
Test passed
Conductor cross section short circuit testing
10
Short-time current
1.2 kA
Result of thermal test
Test passed
Proof of thermal characteristics (needle flame) effective duration
30
Oscillation, broadband noise test result
Test passed
Test specification, oscillation, broadband noise
DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum
Service life test category 1, class B, body mounted
Test frequency
f1 = 5 Hz to f2 = 150 Hz
ASD level
1.857 (m/s2)2/Hz
Acceleration
0,8 g
Test duration per axis
5
Test directions
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
DIN EN 50155 (VDE 0115-200):2008-03
Shock form
Half-sine
Acceleration
5g
Shock duration
30
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
13
End cover width
10
Length
53.3 mm
Height
37
Pitch
13
Connection data
Connection
1
Connection method
Bolt connection
Screw thread
M5
Stripping length
The stripping length depends on the specification provided by the cable lug manufacturer.
Connection in acc. with standard
IEC 60947-7-1
Cable lug connection according to standard
DIN 46234:1980-03
Min. cross section for cable lug connection
0.1 mm²
Max. cross section for cable lug connection
10
AWG min
26
AWG max
8
Hole diameter, min.
5.3 mm
Cable lug width, max.
10
Bolt diameter
5
Tightening torque, min
2
Tightening torque max
2.2 Nm
Cable lug connection according to standard
DIN 46237:1970-07
Min. cross section for cable lug connection
0.5 mm²
Max. cross section for cable lug connection
6
AWG min
20
AWG max
10
Tightening torque max
22
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Standards and Regulations
Connection in acc. with standard
CUL
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values