Product Description:
Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, width 13 mm, color: gray

GTIN
: 04046356534789
Series
: RBO 5-F/8
Type
: Boutaansluitklem
Key Features
- Feed-through terminal block with bolt connection method
- cross section: 0.1 - 6 mm²
- AWG: 26 - 10
- width 13 mm
- color: gray
Advantages
• Direct mounting in control boxes
• Compact connection with ring and fork-type cable lugs
• Bridge shaft for potential distribution using standard screw bridges
• Isolator bridge bar for switchable cross connections
Training Data Goes here
General
Number of levels
1
Number of connections
16
Potentials
8
Nominal cross section
10
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.82 W
Maximum load current
57 A (with 10 mm² conductor cross section)
Nominal current IN
57
Nominal voltage UN
800
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
28
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
121.7 mm
Length
53.3 mm
Height
37
Pitch
13
Connection data
Connection
1
Connection method
Bolt connection
Stripping length
The stripping length depends on the specification provided by the cable lug manufacturer.
Connection in acc. with standard
IEC 60947-7-1
Cable lug connection according to standard
DIN 46234:1980-03
Min. cross section for cable lug connection
0.1 mm²
Max. cross section for cable lug connection
10
AWG min
26
AWG max
8
Hole diameter, min.
5.3 mm
Cable lug width, max.
10
Bolt diameter
5
Screw thread
M5
Tightening torque, min
2
Tightening torque max
2.2 Nm
Cable lug connection according to standard
DIN 46237:1970-07
Min. cross section for cable lug connection
0.5 mm²
Max. cross section for cable lug connection
6
AWG min
20
AWG max
10
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values