Plug, left element, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 1, number of positions: 1, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 41.2 mm, color: green-yellow
GTIN
: 04055626285269
Series
: PP 2,5/ 1-L GNYE
Type
: Connector
Key Features
- Plug
- left element
- nom. voltage: 800 V
- nominal current: 24 A
- connection method: Push-in connection
- number of connections: 1
- number of positions: 1
- cross section: 0.14 mm² - 4 mm²
- AWG: 26 - 12
- width: 5.2 mm
- height: 41.2 mm
- color: green-yellow
Advantages
• The Push-in technology COMBI plugs for self-assembly provide solutions that users can implement themselves
Training Data Goes here
General
Number of positions
1
Number of levels
1
Number of connections
1
Potentials
1
Nominal cross section
2.5 mm²
Color
green-yellow
Insulating material
PA
Flammability rating according to UL 94
V0
Area of application
Machine building
Area of application
Plant engineering
Assembly instructions
Use of a parallel pressing tool is recommended for easy latching of the COMBI connector and coupling elements for self-assembly
Rated surge voltage
6
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
0.77 W
Maximum load current
24 A (with 4 mm² conductor cross section)
Nominal current IN
24
Nominal voltage UN
800
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
5.2 mm
Length
16
Height
41.2 mm
Height
25.6 mm
Pitch
5.2 mm
Connection data
Connection
1
Connection method
Push-in connection
Stripping length
8 mm ... 10 mm
Connection in acc. with standard
IEC 61984
Conductor cross section solid min.
0.14 mm²
Conductor cross section solid max.
4
Conductor cross section AWG min.
26
Conductor cross section AWG max.
12
Conductor cross section flexible min.
0.14 mm²
Conductor cross section flexible max.
2.5 mm²
Min. AWG conductor cross section, flexible
26
Max. AWG conductor cross section, flexible
14
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.14 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
2.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
0.5 mm²
Connection cross sections directly pluggable
0.34 mm² 4 mm²
Conductor cross section solid min.
0.34 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.34 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.34 mm²
Internal cylindrical gage
A3
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e