Product Description:
MCR head-mounted temperature transducers: Programmable loop-powered temperature transducers for resistance thermometers, thermocouples, resistance-type sensors and voltage sensors

GTIN
: 04017918893224
Series
: MCR-FL-HT-T-I
Type
: kopmeetwaardeomvormers
Key Features
- MCR head-mounted temperature transducers: Programmable loop-powered temperature transducers for resistance thermometers
- thermocouples
- resistance-type sensors and voltage sensors
Advantages
• Freely programmable via MCR/PI-CONF-WIN
• For installation in connecting head, form B
• Two-wire transmitter for resistance thermometers, thermocouples, resistance-type sensors, and voltage sensors
Training Data Goes here
Ambient conditions
Ambient temperature (operation)
-40 °C ... 85 °C
Degree of protection
IP00
Degree of protection
IP66 (Installed in the connection head)
Noise immunity
EN 61326-1 (IEC 61326) and NAMUR NE 21
Input data
Configurable/programmable
Yes, programmable
Sensor types (RTD) that can be used
Pt, Ni (100, 500, 1000); minimum measurement range 10 K
Sensor types that can be used (TC)
B, C, D, E, J, K, L, N, R, S, T, U; minimum measurement range 50 K/500 K
Linear resistance measuring range
Resistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to 2000 Ω; minimum measurement range 10 Ω/100 Ω
Connection technology
2-, 3-, 4-conductor
Output data
Output name
Current output
Number of outputs
1
Configurable/programmable
Yes
Current output signal
4 mA ... 20 mA
Current output signal
20 mA ... 4 mA
Output current with wire break
≤ 3.6 mA or ≥ 21 mA (adjustable)
Output current with short-circuit
≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples)
Output current range with overrange/underrange
≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
Load/output load current output
max (Vsupply - 8 V) / 0.025 A (current output)
Power supply
Designation
Loop-powered
Supply voltage range
8 V DC ... 35 V DC
Max. current consumption
< 3.5 mA
Connection data
Connection method
Screw connection
Stripping length
8
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 1.75 mm²
Conductor cross section flexible
0.2 mm² ... 1.75 mm²
Conductor cross section AWG
24 ... 15
General
Transmission error resistance thermometer
0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Transmission error thermocouples
typ. 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Transmission error resistance-type sensor
± 0.1 Ω (10...400 Ω), ± 1.5 Ω (10...2000 Ω)
Transmission error voltage sensor
± 20 µV (-10...100 mV)
Step response (10-90%)
< 2 s
Switch-on delay
6
Test voltage input/output
2 kV (50 Hz, 1 min.)
Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61326-1 (IEC 61326) and NAMUR NE 21
Color
green
Housing material
Polycarbonate, PC
Mounting position
any
Assembly instructions
Connection head according to DIN 43729 form B
Configuration
Using MCR-PI-CONF-WIN configuration software package
Standards and Regulations
Connection in acc. with standard
CUL
Conformance
CE-compliant
UL, USA/Canada
Class I, Div. 2, Groups A, B, C, D
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values
There is no certificate available for this product.