Product Description:
MCR passive current measuring transducer, for sinusoidal alternating currents 0..1 A AC/0..5 A AC, without switching output, output signal 0..10 V/0..20 mA

GTIN
: 04017918148447
Series
: MCR-SLP-1-5-UI-0
Type
: Stroommeetwaardeomvormer
Key Features
- MCR passive current measuring transducer
- for sinusoidal alternating currents 0..1 A AC/0..5 A AC
- without switching output
- output signal 0..10 V/0..20 mA
Advantages
• Loop-powered
• 1 A and 5 A AC measuring ranges, reconnectable
Training Data Goes here
Dimensions
Width
22.5 mm
Height
99
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-25 °C ... 80 °C (non-condensing)
Maximum altitude
< 2000 m
Degree of protection
IP20
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Input data
Input
Current measuring input 1 A
Input current range
0 A AC ... 1 A
Impulse form
Sine
Overload capacity
2 x IN (5 min. at 60°C ambient temperature)
Surge strength
50 A (1 s)
Permissible output range
1.2 x IN
Nominal frequency fN
50
Frequency measuring range
45 Hz ... 60 Hz
Power dissipation
1.6 VA (at IA = 20 mA)
Connection method
Screw connection
Input
Current measuring input 5 A
Input current range
0 A AC ... 5 A
Surge strength
100 A (1 s)
Power dissipation
2.2 VA (I = 20 mA)
Output data
Output name
Voltage output
Voltage output signal
0 V ... 10 V
Max. output voltage
20
Load/output load voltage output
> 100 kΩ
Ripple
< 50 mVPP
Output name
Current output
Current output signal
0 mA ... 20 mA
Max. output current
30
Load/output load current output
< 750 Ω
Residual ripple, in reference to the measured value
0.5 % (pp of measured value)
Switching output
Output name
No switching output
Connection data
Stripping length
8
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
General
Maximum transmission error
< 0.5 % (of final value)
Maximum temperature coefficient
< 0.015 %/K
Step response (10-90%)
< 200 ms
Test voltage
3.5 kV
Protective circuit
Transient protection in the output Suppressor diode
Overvoltage category
III
Degree of pollution
2
Rated insulation voltage
300 V AC (to earth)
Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61000-6-4
Color
green
Housing material
Polyamide PA non-reinforced
Mounting position
< 50 °C: any; > 50 °C: vertical (installation on horizontal DIN rail)
Standards and Regulations
Connection in acc. with standard
CUL
Conformance
CE-compliant
Conformance/approvals
Designation
CE
Identification
CE-compliant
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
There is no accessory available for this product.