Product Description:
Pick-off terminal block, For use with PTPOWER 50, 95, 150, and 185 Power-Turn high-current terminal blocks, nom. voltage: 1500 V, nominal current: 57 A, connection method: Push-in connection, number of connections: 2, cross section: 0.5 mm² - 16 mm², AWG: 20 - 6, width: 18.5 mm, height: 34.7 mm, color: blue, mounting type: on base element

GTIN
: 04046356779081
Series
: AGK 10-PTPOWER BU
Type
: Aftakklem
Key Features
- Pick-off terminal block
- For use with PTPOWER 50
- 95
- 150
- 185 Power-Turn high-current terminal blocks
- nom. voltage: 1500 V
- nominal current: 57 A
- connection method: Push-in connection
- number of connections: 2
- cross section: 0.5 mm² - 16 mm²
- AWG: 20 - 6
- width: 18.5 mm
- height: 34.7 mm
- color: blue
- mounting type: on base element
Advantages
• Large-surface marking
• The fully insulated, optional use pick-off terminal block enables voltage pick-off
• Pick-off terminal block, for snapping into the lateral guide
Training Data Goes here
General
Note
For use with PTPOWER 50, 95, 150, and 185 Power-Turn high-current terminal blocks
Number of levels
1
Number of connections
2
Potentials
1
Nominal cross section
10
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
1.82 W
Maximum load current
57 A (The maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal current IN
57
Nominal voltage UN
1500
Open side panel
No
Relative insulation material temperature index (Elec., UL 746 B)
130
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125
Static insulating material application in cold
-60 °C
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Dimensions
Width
18.5 mm
Length
35
Height
34.7 mm
Connection data
Connection
1
Connection method
Push-in connection
Stripping length
18
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
16
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10
Min. AWG conductor cross section, flexible
20
Max. AWG conductor cross section, flexible
8
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
10
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
10
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
1.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
4
Connection cross sections directly pluggable
1 mm² 16 mm²
Conductor cross section solid min.
1
Conductor cross section flexible, with ferrule without plastic sleeve min.
4
Conductor cross section flexible, with ferrule with plastic sleeve min.
2.5 mm²
Internal cylindrical gage
A6
Ambient conditions
Operating temperature
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport)
30 % ... 70 %
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values