Siemens SIRIUS compact load feeder direct on-line starter 690 V, 24 V AC/DC - 3RA6120-0BB30
Product Description:
SIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 0.32...1.25 A IP20 Connection main circuit: plug-in, without terminals Connection auxiliary circuit: plug-in, without terminals

GTIN
: 04011209778511
Series
: SIRIUS Compact load feeder DOL star
Key Features
- SIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 0.32...1.25 A IP20 Connection main circuit: plug-in
- without terminals Connection auxiliary circuit: plug-in
- without terminals
Training Data Goes here
General technical data
product function control circuit interface to parallel wiring
Yes
product extension auxiliary switch
Yes
power loss [W] for rated value of the current at AC in hot operating state
0.01 W
● per pole
0.01 W
power loss [W] for rated value of the current without load current share typical
2.9 W
insulation voltage rated value
690 V
degree of pollution
3
surge voltage resistance rated value
6 000 V
maximum permissible voltage for safe isolation
----
● between main and auxiliary circuit
400 V
● between auxiliary and auxiliary circuit
250 V
● between control and auxiliary circuit
300 V
degree of protection NEMA rating
other
shock resistance
a=60 m/s2 (6g) with 10 ms per 3 shocks in all axes
vibration resistance
f= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles
mechanical service life (switching cycles)
----
● of the main contacts typical
10 000 000
● of auxiliary contacts typical
10 000 000
● of the signaling contacts typical
10 000 000
electrical endurance (switching cycles) of auxiliary contacts
----
● at DC-13 at 6 A at 24 V typical
30 000
● at AC-15 at 6 A at 230 V typical
200 000
type of assignment
continous operation according to IEC 60947-6-2
reference code acc. to IEC 81346-2
Q
Substance Prohibitance (Date)
01.05.2012 00:00:00
Ambient conditions
installation altitude at height above sea level maximum
2 000 m
ambient temperature
----
● during operation
-20 ... +60 °C
● during storage
-55 ... +80 °C
● during transport
-55 ... +80 °C
relative humidity during operation
10 ... 90 %
Main circuit
number of poles for main current circuit
3
adjustable current response value current of the current-dependent overload release
0.1 ... 0.4 A
formula for making capacity limit current
120 x Ie
formula for breaking capacity limit current
100 x Ie
yielded mechanical performance for 4-pole AC motor
----
● at 400 V rated value
0.09 kW
● at 500 V rated value
0.12 kW
● at 690 V rated value
0.18 kW
operating voltage at AC-3 rated value maximum
690 V
operational current
----
● at AC at 400 V rated value
0.4 A
● at AC-43
----
— at 400 V rated value
0.3 A
— at 500 V rated value
0.32 A
— at 690 V rated value
0.35 A
operating power
----
● at AC-3 at 400 V rated value
90 W
— at 400 V rated value
90 W
— at 500 V rated value
120 W
— at 690 V rated value
180 W
no-load switching frequency
3 600 1/h
operating frequency
----
● at AC-41 acc. to IEC 60947-6-2 maximum
750 1/h
● at AC-43 acc. to IEC 60947-6-2 maximum
250 1/h
Control circuit/ Control
type of voltage
AC/DC
control supply voltage 1 at AC
----
● at 50 Hz rated value
24 V
● at 60 Hz rated value
24 V
control supply voltage frequency
----
● 1 rated value
50 Hz
● 2 rated value
60 Hz
control supply voltage 1
----
● at DC rated value
24 V
holding power
----
● at AC maximum
2.8 W
● at DC maximum
2.9 W
Auxiliary circuit
number of NC contacts for auxiliary contacts
1
number of NO contacts for auxiliary contacts
1
number of NO contacts of instantaneous short-circuit trip unit for signaling contact
1
number of CO contacts of the current-dependent overload release for signaling contact
1
operational current of auxiliary contacts at AC-12 maximum
10 A
operational current of auxiliary contacts at DC-13 at 250 V
0.27 A
Protective and monitoring functions
trip class
CLASS 10 and 20 adjustable
breaking capacity operating short-circuit current (Ics)
----
● at 400 V
53 kA
● at 500 V rated value
3 kA
● at 690 V rated value
3 kA
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
----
● at 480 V rated value
0.4 A
● at 600 V rated value
0.4 A
contact rating of auxiliary contacts according to UL
contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300
Short-circuit protection
product function short circuit protection
Yes
design of short-circuit protection
electromagnetic
design of the fuse link
----
● for short-circuit protection of the auxiliary switch required
fuse gL/gG: 10 A
● for short-circuit protection of the signaling switch of the short-circuit release required
6A gL/gG/400V
● for short-circuit protection of the signaling switch of the overload release required
4A gL/gG/400V
Installation/ mounting/ dimensions
mounting position
any
● recommended
vertical, on horizontal standard mounting rail
fastening method
screw and snap-on mounting
height
170 mm
width
45 mm
depth
165 mm
Connections/ Terminals
product function
----
● removable terminal for main circuit
Yes
● removable terminal for auxiliary and control circuit
Yes
type of electrical connection
----
● for main current circuit
plug-in without terminals
● for auxiliary and control circuit
plug-in without terminals
Safety related data
B10 value with high demand rate acc. to SN 31920
3 000 000
proportion of dangerous failures
----
● with low demand rate acc. to SN 31920
40 %
● with high demand rate acc. to SN 31920
50 %
failure rate [FIT] with low demand rate acc. to SN 31920
100 FIT
T1 value for proof test interval or service life acc. to IEC 61508
20 y
protection class IP on the front acc. to IEC 60529
IP20
touch protection on the front acc. to IEC 60529
finger-safe
Communication/ Protocol
product function bus communication
No
protocol is supported
----
● AS-Interface protocol
No
● IO-Link protocol
No
product function control circuit interface with IO link
No
Electromagnetic compatibility
conducted interference
----
● due to burst acc. to IEC 61000-4-4
4 kV main contacts, 2 kV auxiliary contacts
● due to conductor-earth surge acc. to IEC 61000-4-5
4 kV main contacts, 2 kV auxiliary contacts
● due to conductor-conductor surge acc. to IEC 61000-4-5
2 kV main contacts, 1 kV auxiliary contacts
● due to high-frequency radiation acc. to IEC 61000-4-6
0.15-80Mhz at 10V
field-based interference acc. to IEC 61000-4-3
10 V/m
electrostatic discharge acc. to IEC 61000-4-2
8 kV
conducted HF interference emissions acc. to CISPR11
150 kHz ... 30 MHz Class A
field-bound HF interference emission acc. to CISPR11
30 ... 1000 MHz Class A
Supply voltage
Supply voltage required Auxiliary voltage
No
Display
number of LEDs
2
Material Declaration "Green Passport" other (pdf 78 KB)
LinkRoHS Compliance other (pdf 46 KB)
LinkEU-Declaration of Conformity Declaration of Conformity (pdf 501 KB)
LinkMaterial Documentation other (pdf 124 KB)
LinkCCC Self Declaration General Product Approval (pdf 649 KB)
LinkType Approval Certificate Marine / Shipping (pdf 497 KB)
LinkType Approval Certificate Marine / Shipping (pdf 258 KB)
LinkCertificate of Design Assessment Marine / Shipping (pdf 1302 KB)
LinkEAC Certificate General Product Approval (pdf 1464 KB)
LinkEAC Certificate General Product Approval (pdf 3608 KB)
LinkEAC Certificate General Product Approval (pdf 1468 KB)
LinkEAC Certificate General Product Approval (pdf 1660 KB)
LinkType Approval Certificate Marine / Shipping (pdf 417 KB)
LinkType Approval Certificate Marine / Shipping (pdf 150 KB)
LinkRadioactive Material in Products other (pdf 65 KB)
LinkType Test Certificate ( according Product-Standards ) Test Certificates (pdf 182 KB)
LinkType Approval Certificate Marine / Shipping (pdf 147 KB)
LinkCSA Certificate of Compliance General Product Approval (pdf 179 KB)
LinkUL Certificate of Compliance General Product Approval (pdf 277 KB)
LinkChinese Quality Check Mark other (pdf 67 KB)
Linksilicone-free other (pdf 51 KB)
LinkUL Certificate of Compliance General Product Approval (pdf 286 KB)
LinkSuppliers declaration of conformity EMC (pdf 74 KB)
LinkType Approval Certificate Marine / Shipping (pdf 161 KB)
LinkVDE Type Examination Certificate Functional Safety/Safety of Machinery (pdf 385 KB)
Link